Bringing light to the reading room
Frontiers in Radiology · 12.06.2026 · 6
DOI: 10.3389/fradi.2026.1821486 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Radiology, online erschienen am 12.06.2026. Verfasst von Christine Joyce und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, West Virginia University, Morgantown, WV, United States. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIGMS NIH HHS, National Institute of General Medical Sciences.
Abstract (Originalsprache)
Background
According to the American College of Radiology (ACR) Technical Standard Guidelines, there is a recommended illuminance level for reading rooms set between 25 and 75 lux. However, these guidelines are based on studies completed in 2007–2009, which predate significant advancements in display technology. No recent study has re-evaluated these lighting conditions, and more specifically, no prior studies have examined the effects of ambient lighting on the detection of intracranial hemorrhage on non-contrast brain CT.
Objective
To determine if higher ambient lighting levels (> 400 lux) significantly effects the diagnostic accuracy of board-certified neuroradiologists in detecting intracranial hemorrhage on brain CT, compared with standard low-light reading room conditions (20–70 lux).
Methods
Forty-two standard-of-care non-contrast head CT scans (axial acquisitions with coronal/sagittal reformats) from a tertiary-care hospital were selected by two independent neuroradiologists. These neuroradiologists established the presence or absence of intracranial hemorrhage. Four additional board-certified neuroradiologists independently interpreted all cases twice: first in a brightly lit environment (> 400 lux, measured at desktop level) and, after a > 6-month washout period to minimize recognition memory bias, in a standard reading room (20–70 lux). Interpretations were performed on calibrated Barco MDNC-3421 displays using the institutional Fuji PACS. Sensitivity, specificity, and accuracy were calculated for each condition and compared using paired two-tailed t-tests with Bonferroni correction for multiple comparisons.
Results
No statistically significant differences were found between bright and dark conditions for sensitivity (0.974 vs. 0.974, p = 1.00), specificity (0.978 vs. 1.0, p = 0.49 adjusted), or overall accuracy (0.976 vs. 0.988, p = 1.00 adjusted).
Conclusion
Increased ambient lighting levels (> 400 lux) do not significantly affect the ability of board-certified neuroradiologists to accurately detect intracranial hemorrhage on modern high-resolution displays. These findings suggest that current guidelines should be re-evaluated with recent improvements in technology. Larger multi-center studies are warranted to confirm these results across additional pathologies and modalities.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, West Virginia University, Morgantown, WV, United States.
- Department of Neuroradiology, West Virginia University, Morgantown, WV, United States.
- West Virginia Clinical and Translational Sciences Institute, Morgantown, WV, United States.
Förderung
- NIGMS NIH HHS
- National Institute of General Medical Sciences
Zitieren
APA
Joyce, C., Kassar, M. A., Knecht, A., Jung, M., Joseph, J., McCloskey, J., Intrapiromkul, J., Lakhani, D. A., & McGaughey, T. (2026). Bringing light to the reading room. Frontiers in Radiology, 6. https://doi.org/10.3389/fradi.2026.1821486
Vancouver
Joyce C, Kassar MA, Knecht A, Jung M, Joseph J, McCloskey J, et al. Bringing light to the reading room. Frontiers in Radiology. 2026;6. doi:10.3389/fradi.2026.1821486
BibTeX
@article{Joyce2026,
author = {Joyce, Christine and Kassar, Mohammad Adam and Knecht, Alexandria and Jung, Melissa and Joseph, Joe and McCloskey, Justin and Intrapiromkul, Jarunee and Lakhani, Dhairya A and McGaughey, Tyler},
title = {Bringing light to the reading room},
journal = {Frontiers in Radiology},
year = {2026},
volume = {6},
doi = {10.3389/fradi.2026.1821486}
}
EUVIMED