EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

AI in the Loop: functionalizing fold performance disagreement to monitor automated medical image segmentation workflows

Harrison C Gottlich, Panagiotis Korfiatis, Adriana V Gregory, Timothy L Kline

Frontiers in Radiology · 15.09.2023 · 3

DOI: 10.3389/fradi.2023.1223294 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Radiology, online erschienen am 15.09.2023. Verfasst von Harrison C Gottlich und 3 weiteren Autor:innen. Beteiligte Einrichtung: Mayo Clinic Alix School of Medicine, Mayo Clinic, Rochester, MN, United States. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIDDK NIH HHS, National Institute of Diabetes and Digestive, Kidney Diseases of the National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Methods that automatically flag poor performing predictions are drastically needed to safely implement machine learning workflows into clinical practice as well as to identify difficult cases during model training.

Methods

Disagreement between the fivefold cross-validation sub-models was quantified using dice scores between folds and summarized as a surrogate for model confidence. The summarized Interfold Dices were compared with thresholds informed by human interobserver values to determine whether final ensemble model performance should be manually reviewed.

Results

The method on all tasks efficiently flagged poor segmented images without consulting a reference standard. Using the median Interfold Dice for comparison, substantial dice score improvements after excluding flagged images was noted for the in-domain CT (0.85 ± 0.20 to 0.91 ± 0.08, 8/50 images flagged) and MR (0.76 ± 0.27 to 0.85 ± 0.09, 8/50 images flagged). Most impressively, there were dramatic dice score improvements in the simulated out-of-distribution task where the model was trained on a radical nephrectomy dataset with different contrast phases predicting a partial nephrectomy all cortico-medullary phase dataset (0.67 ± 0.36 to 0.89 ± 0.10, 122/300 images flagged).

Discussion

Comparing interfold sub-model disagreement against human interobserver values is an effective and efficient way to assess automated predictions when a reference standard is not available. This functionality provides a necessary safeguard to patient care important to safely implement automated medical image segmentation workflows.

Schlagwörter

Stichwörter der Autor:innen

AI in the loopconvolutional neural networksdeep learningepistemic uncertaintymachine learning model performancesemantic segmentationsimilarity metrics

Autor:innen und Institutionen

  • Mayo Clinic Alix School of Medicine, Mayo Clinic, Rochester, MN, United States.
  • Department of Radiology, Mayo Clinic, Rochester, MN, United States.
  • Division of Nephrology and Hypertension, Mayo Clinic, Rochester, MN, United States.

Förderung

  • NIDDK NIH HHS
  • National Institute of Diabetes and Digestive
  • Kidney Diseases of the National Institutes of Health

Zitieren

APA

Gottlich, H. C., Korfiatis, P., Gregory, A. V., & Kline, T. L. (2023). AI in the Loop: functionalizing fold performance disagreement to monitor automated medical image segmentation workflows. Frontiers in Radiology, 3. https://doi.org/10.3389/fradi.2023.1223294

Vancouver

Gottlich HC, Korfiatis P, Gregory AV, Kline TL. AI in the Loop: functionalizing fold performance disagreement to monitor automated medical image segmentation workflows. Frontiers in Radiology. 2023;3. doi:10.3389/fradi.2023.1223294

BibTeX
@article{Gottlich2023,
  author = {Gottlich, Harrison C and Korfiatis, Panagiotis and Gregory, Adriana V and Kline, Timothy L},
  title = {AI in the Loop: functionalizing fold performance disagreement to monitor automated medical image segmentation workflows},
  journal = {Frontiers in Radiology},
  year = {2023},
  volume = {3},
  doi = {10.3389/fradi.2023.1223294}
}