Validity, reliability, and readability of large language model chatbots for melanoma public education: a cross-sectional comparative study
Frontiers in Public Health · 16.11.2026 · 14
DOI: 10.3389/fpubh.2026.2000750 ↗Kurz gefasst
Querschnittstudie in der Zeitschrift Frontiers in Public Health, online erschienen am 16.11.2026. Verfasst von Yi Wei und 5 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Large language model (LLM)-based chatbots are increasingly used for health information, but their suitability for melanoma public education requires evaluation across accuracy, information quality, transparency, and readability.
Methods
We compared ChatGPT-5.6, DeepSeek-V4, Claude Sonnet 5, and Gemini 3.5 Flash. Validity was assessed using 200 melanoma-related single-best-answer multiple-choice questions administered in three independent trials. Fifteen core public-education questions were developed from worldwide Google Trends data and clinical experience. Responses were evaluated using DISCERN, EQIP, GQS, and JAMA benchmarks, and readability was assessed using ARI, Coleman–Liau, FKGL, FRES, GFI, and SMOG indices.
Results
Mean MCQ accuracy was highest for ChatGPT-5.6 (94.0% ± 0.5%), followed by Gemini 3.5 Flash (92.5% ± 1.3%), Claude Sonnet 5 (87.2% ± 1.4%), and DeepSeek-V4 (79.3% ± 0.3%; p < 0.001). ChatGPT-5.6 achieved the highest DISCERN (52.07 ± 9.48), EQIP (81.67 ± 4.08), and GQS (4.40 ± 0.51) scores. JAMA transparency scores were low across models. Gemini 3.5 Flash showed the most favorable overall readability profile; however, mean grade-level indices for all models exceeded the sixth-grade benchmark, and all mean FRES scores were below the recommended range.
Conclusion
Current LLM chatbots show substantial potential for melanoma education, but performance varies across validity, quality, transparency, and readability. Their use should remain supplementary, with improved source transparency and health-literacy–appropriate language required before broader patient-facing implementation.
Zitieren
APA
Wei, Y., Yu, T., Tang, D., Xiong, T., Li, L., & Liao, J. (2026). Validity, reliability, and readability of large language model chatbots for melanoma public education: a cross-sectional comparative study. Frontiers in Public Health, 14. https://doi.org/10.3389/fpubh.2026.2000750
Vancouver
Wei Y, Yu T, Tang D, Xiong T, Li L, Liao J. Validity, reliability, and readability of large language model chatbots for melanoma public education: a cross-sectional comparative study. Frontiers in Public Health. 2026;14. doi:10.3389/fpubh.2026.2000750
BibTeX
@article{Wei2026,
author = {Wei, Yi and Yu, Tianjing and Tang, Daitian and Xiong, Tianyu and Li, Li and Liao, Junlin},
title = {Validity, reliability, and readability of large language model chatbots for melanoma public education: a cross-sectional comparative study},
journal = {Frontiers in Public Health},
year = {2026},
volume = {14},
doi = {10.3389/fpubh.2026.2000750}
}
EUVIMED