EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Bacterial contamination in the different parts of household air conditioners: a comprehensive evaluation from Chengdu, Southwest China

Donglei Sun, Li Tang, Keyan Long, Weilian Sun, Zunzhen Zhang

Frontiers in Public Health · 2024

DOI: 10.3389/fpubh.2024.1429626 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Public Health, 2024. Verfasst von Donglei Sun und 4 weiteren Autor:innen. Beteiligte Einrichtung: West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, China. Hauptthemen laut MEDLINE: Air Microbiology, Air Pollution, Indoor, Bacteria, Air Conditioning. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Air flow driven by air-conditioner has a significant impact on the indoor environment, however, the bacterial contamination conditions in the different parts of air-conditioners have not been fully elucidated.

Methods

In this study, we assessed the bacterial pollution in the four parts, including air outlet, filter net, cooling fin and water sink, of ten household air-conditioners quantitatively and qualitatively from Chengdu, southwestern China.

Results

The microbial cultivation results showed the large total bacterial counts of 5042.0, 9127.6, 6595.1, and 12296.2 CFU/cm 2 in air outlet, filter net, cooling fin, and water sink. Furthermore, the sequencing data showed that these four parts displayed different bacterial characteristics. At the level of genus, Caproiciproducens and Acidipropionibacterium were predominant in air outlet. Bacillus, Acinetobacter, Paracoccus , and Corynebacterium were detected as the characteristic bacteria in filter net. For cooling fin, Rhodococcus, Achromobacter , and Nocardioides were the dominant bacteria. The genera of Methylobacterium-Methylorubrum, Brevibacterium, Stenotrophomonas , and Psychrobacter were identified as the bioindicators in water sink. The bioinformatic analysis on the sequencing data illustrated that the bacteria from air-conditioners were associated with metabolic disturbance.

Discussion

This study reveals the distinct bacterial compositions in the different parts of air-conditioner, and provides new clues for the non-negligible bacterial pollution in this common appliance from Chinese households.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Air MicrobiologyAir Pollution, IndoorBacteriaAir ConditioningChinaHumansEnvironmental Monitoring

Stichwörter der Autor:innen

16S ribosomal RNA gene sequencingbacteriumhousehold air-conditionerindoor environmentmicrobial contamination

Autor:innen und Institutionen

  • West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, China.

Zitieren

APA

Sun, D., Tang, L., Long, K., Sun, W., & Zhang, Z. (2024). Bacterial contamination in the different parts of household air conditioners: a comprehensive evaluation from Chengdu, Southwest China. Frontiers in Public Health. https://doi.org/10.3389/fpubh.2024.1429626

Vancouver

Sun D, Tang L, Long K, Sun W, Zhang Z. Bacterial contamination in the different parts of household air conditioners: a comprehensive evaluation from Chengdu, Southwest China. Frontiers in Public Health. 2024. doi:10.3389/fpubh.2024.1429626

BibTeX
@article{Sun2024,
  author = {Sun, Donglei and Tang, Li and Long, Keyan and Sun, Weilian and Zhang, Zunzhen},
  title = {Bacterial contamination in the different parts of household air conditioners: a comprehensive evaluation from Chengdu, Southwest China},
  journal = {Frontiers in Public Health},
  year = {2024},
  doi = {10.3389/fpubh.2024.1429626}
}