Assessment of indoor air quality in health clubs: insights into (ultra)fine and coarse particles and gaseous pollutants
Frontiers in Public Health · 28.11.2023 · 11
DOI: 10.3389/fpubh.2023.1310215 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Public Health, online erschienen am 28.11.2023. Verfasst von Cátia Peixoto und 3 weiteren Autor:innen. Beteiligte Einrichtung: REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida, Porto, Portugal. Hauptthemen laut MEDLINE: Air Pollution, Indoor, Air Pollutants, Environmental Pollutants, Fitness Centers. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 80 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Exercising on regular basis provides countless health benefits. To ensure the health, well-being and performance of athletes, optimal indoor air quality, regular maintenance and ventilation in sport facilities are essential.
Methods
This study assessed the levels of particulate, down to the ultrafine range (PM 10 , PM 2.5 , and particle number concentration in size range of 20–1,000 nm, i.e., – PNC 20-1000 nm ), gaseous pollutants (total volatile organic compounds – TVOCs, CO 2 , and O 3 ) and comfort parameters (temperature – T, relative humidity – RH) in different functional spaces of health clubs ( n = 8), under specific occupancy and ventilation restrictions. Results and Discussion In all HCs human occupancy resulted in elevated particles (up to 2–3 times than those previously reported), considering mass concentrations (PM 10 : 1.9–988.5 μg/m 3 PM 2.5 : 1.6–479.3 μg/m 3 ) and number (PNC 1.23 × 10 3 – 9.14 × 10 4 #/cm 3 ). Coarse and fine PM indicated a common origin (r s = 0.888–0.909), while PNC showed low–moderate associations with particle mass (r s = 0.264–0.629). In addition, up to twice-higher PM and PNC were detected in cardiofitness & bodybuilding (C&B) areas as these spaces were the most frequented, reinforcing the impacts of occupational activities. In all HCs, TVOCs (0.01–39.67 mg/m 3 ) highly exceeded the existent protection thresholds (1.6–8.9 times) due to the frequent use of cleaning products and disinfectants (2–28 times higher than in previous works). On contrary to PM and PNC, TVOCs were higher (1.1–4.2 times) in studios than in C&B areas, due to the limited ventilations combined with the smaller room areas/volumes. The occupancy restrictions also led to reduced CO 2 (122–6,914 mg/m 3 ) than previously observed, with the lowest values in HCs with natural airing. Finally, the specific recommendations for RH and T in sport facilities were largely unmet thus emphasizing the need of proper ventilation procedures in these spaces.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida, Porto, Portugal.
- LEPABE-ALiCE, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, Porto, Portugal.
Zitieren
APA
Peixoto, C., Pereira, M. D. C., Morais, S., & Slezakova, K. (2023). Assessment of indoor air quality in health clubs: insights into (ultra)fine and coarse particles and gaseous pollutants. Frontiers in Public Health, 11. https://doi.org/10.3389/fpubh.2023.1310215
Vancouver
Peixoto C, Pereira MDC, Morais S, Slezakova K. Assessment of indoor air quality in health clubs: insights into (ultra)fine and coarse particles and gaseous pollutants. Frontiers in Public Health. 2023;11. doi:10.3389/fpubh.2023.1310215
BibTeX
@article{Peixoto2023,
author = {Peixoto, Cátia and Pereira, Maria do Carmo and Morais, Simone and Slezakova, Klara},
title = {Assessment of indoor air quality in health clubs: insights into (ultra)fine and coarse particles and gaseous pollutants},
journal = {Frontiers in Public Health},
year = {2023},
volume = {11},
doi = {10.3389/fpubh.2023.1310215}
}
EUVIMED