EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Loop-mediated isothermal amplification combined with lateral flow biosensor for rapid and sensitive detection of monkeypox virus

Xiaolan Huang, Fei Xiao, Nan Jia, Chunrong Sun, Jin Fu, Zheng Xu, Xiaodai Cui, Hui Huang, Dong Qu, Juan Zhou, Yi Wang

Frontiers in Public Health · 2023

DOI: 10.3389/fpubh.2023.1132896 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Public Health, 2023. Verfasst von Xiaolan Huang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Experimental Research Center, Capital Institute of Pediatrics, Beijing, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Monkeypox virus. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The ongoing outbreak of the monkeypox, caused by monkeypox virus (MPXV), has been a public health emergency of international concern, indicating an urgent need for rapid and sensitive MPXV detection. Here, we designed a diagnostic test based on loop-mediated isothermal amplification (LAMP) and nanoparticle-based lateral flow biosensor(LFB)for diagnosis of MPXV infection, termed MPX-LAMP-LFB. A set of six LAMP primers was designed based the ATI gene of MPXV, and LAMP amplification of MPXV templates was performed at 63°C for only 40 min. The results were rapidly and visually decided using the LFB test within 2 min. The MPX-LAMP-LFB assay can specifically detect MPXV strains without cross-reaction with non-MPXV pathogens. The sensitivity of the MPX-LAMP-LFB assay is as low as 5 copies/μl of plasmid template and 12.5 copies/μl of pseudovirus in human blood samples. The whole process of the MPX-LAMP-LFB assay could be completed ~1 h, including rapid template preparation (15 min), LAMP reaction (40 min)and result reporting (<2 min). Collectively, MPX-LAMP-LFB assay developed here is a useful tool for rapid and reliable diagnosis of MPXV infection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesMonkeypox virusHumansNucleic Acid Amplification TechniquesSensitivity and SpecificityMpox, MonkeypoxMolecular Diagnostic Techniques

Stichwörter der Autor:innen

diagnosislateral flow biosensorloop-mediated isothermal amplificationmonkeypox virusnanoparticles

Autor:innen und Institutionen

  • Experimental Research Center, Capital Institute of Pediatrics, Beijing, China.
  • Department of Infectious Diseases, Children's Hospital Affiliated Capital Institute of Pediatrics, Beijing, China.
  • Department of Critical Medicine, Children's Hospital Affiliated Capital Institute of Pediatrics, Beijing, China.

Zitieren

APA

Huang, X., Xiao, F., Jia, N., Sun, C., Fu, J., Xu, Z., Cui, X., Huang, H., Qu, D., Zhou, J., & Wang, Y. (2023). Loop-mediated isothermal amplification combined with lateral flow biosensor for rapid and sensitive detection of monkeypox virus. Frontiers in Public Health. https://doi.org/10.3389/fpubh.2023.1132896

Vancouver

Huang X, Xiao F, Jia N, Sun C, Fu J, Xu Z, et al. Loop-mediated isothermal amplification combined with lateral flow biosensor for rapid and sensitive detection of monkeypox virus. Frontiers in Public Health. 2023. doi:10.3389/fpubh.2023.1132896

BibTeX
@article{Huang2023,
  author = {Huang, Xiaolan and Xiao, Fei and Jia, Nan and Sun, Chunrong and Fu, Jin and Xu, Zheng and Cui, Xiaodai and Huang, Hui and Qu, Dong and Zhou, Juan and Wang, Yi},
  title = {Loop-mediated isothermal amplification combined with lateral flow biosensor for rapid and sensitive detection of monkeypox virus},
  journal = {Frontiers in Public Health},
  year = {2023},
  doi = {10.3389/fpubh.2023.1132896}
}
Kostenlos starten →