EUVIMEDEUVIMED entdecken
Systematische ÜbersichtOpen Access · CC BY 4.0

Accuracy of Raman spectroscopy in the diagnosis of Alzheimer's disease

Yanmei Xu, Xinyu Pan, Huan Li, Qiongfang Cao, Fan Xu, Jianshu Zhang

Frontiers in Psychiatry · 16.03.2023 · 14

DOI: 10.3389/fpsyt.2023.1112615 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Frontiers in Psychiatry, online erschienen am 16.03.2023. Verfasst von Yanmei Xu und 5 weiteren Autor:innen. Beteiligte Einrichtung: General Practice Ward/International Medical Center Ward, General Practice Medical Center, West China Hospital, Sichuan University, Chengdu, Sichuan, …. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To systematically evaluate the accuracy of Raman spectroscopy in the diagnosis of Alzheimer's disease.

Methods

Databases including Web of Science, PubMed, The Cochrane Library, EMbase, CBM, CNKI, Wan Fang Data, and VIP were electronically searched for studies on Raman spectroscopy in diagnosis of Alzheimer's disease from inception to November 2022. Two reviewers independently screened the literature, extracted data, and assessed the risk of bias in the included studies. Then, meta-analysis was performed using Meta-Disc1.4 and Stata 16.0 software.

Results

A total of eight studies were finally included. The pooled sensitivity of Raman spectroscopy was 0.86 [95% CI (0.80–0.91)], specificity was 0.87 [95% CI (0.79–0.92)], positive likelihood ratio was 5.50 [95% CI (3.55–8.51)], negative likelihood ratio was 0.17 [95% CI (0.09–0.34)], diagnosis odds ratio and area under the curve of SROC were 42.44 [95% CI (19.80–90.97)] and 0.931, respectively. Sensitivity analysis was carried out after each study was excluded one by one, and the results showed that pooled sensitivity and specificity had no significant change, indicating that the stability of the meta-analysis results was great.

Conclusions

Our findings indicated that Raman spectroscopy had high accuracy in the diagnosis of AD, though it still did not rule out the possibility of misdiagnosis and missed diagnosis. Limited by the quantity and quality of the included studies, the above conclusions need to be verified by more high-quality studies.

Schlagwörter

Stichwörter der Autor:innen

Alzheimer's diseaseRaman spectroscopydiagnosismeta-analysissensitivity and specificity

Autor:innen und Institutionen

  • General Practice Ward/International Medical Center Ward, General Practice Medical Center, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
  • School of Pharmacy, Chengdu Medical College, Chengdu, Sichuan, China.
  • Department of Public Health, Chengdu Medical College, Chengdu, Sichuan, China.

Zitieren

APA

Xu, Y., Pan, X., Li, H., Cao, Q., Xu, F., & Zhang, J. (2023). Accuracy of Raman spectroscopy in the diagnosis of Alzheimer's disease. Frontiers in Psychiatry, 14. https://doi.org/10.3389/fpsyt.2023.1112615

Vancouver

Xu Y, Pan X, Li H, Cao Q, Xu F, Zhang J. Accuracy of Raman spectroscopy in the diagnosis of Alzheimer's disease. Frontiers in Psychiatry. 2023;14. doi:10.3389/fpsyt.2023.1112615

BibTeX
@article{Xu2023,
  author = {Xu, Yanmei and Pan, Xinyu and Li, Huan and Cao, Qiongfang and Xu, Fan and Zhang, Jianshu},
  title = {Accuracy of Raman spectroscopy in the diagnosis of Alzheimer's disease},
  journal = {Frontiers in Psychiatry},
  year = {2023},
  volume = {14},
  doi = {10.3389/fpsyt.2023.1112615}
}