EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Structured multifrequency segmental bioimpedance descriptors for diabetes screening support

Minho Choi, Kun Ho Lee, Jaeuk U Kim

Frontiers in Physiology · 29.10.2026 · 17

DOI: 10.3389/fphys.2026.1958735 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Physiology, online erschienen am 29.10.2026. Verfasst von Minho Choi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Life Science Research Division, Korea Institute of Oriental Medicine, Daejeon, Republic of Korea. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Blood-based measurements remain the standard for identifying diabetes mellitus (DM), but repeatable non-invasive approaches may have value for screening support. Bioelectrical impedance analysis (BIA) captures body-composition, hydration, and bioelectrical properties associated with metabolic health. However, previous studies have largely focused on analyzer-derived body-composition variables or individual parameters such as phase angle, whereas multifrequency segmental impedance responses have not been systematically characterized for screening-support applications. This study aimed to computationally characterize multifrequency segmental BIA responses using structured descriptors and to evaluate their potential for identifying previously diagnosed DM status within a proof-of-concept screening-support framework.

Methods

An ExtraTrees-based classification framework was developed to discriminate previously diagnosed DM status. Feature selection, input dimensionality determination, and model optimization were performed within a nested cross-validation framework, and performance was evaluated using pooled out-of-fold predictions. Alongside demographic and device-derived body-composition variables, we formulated 440 base BIA descriptors capturing amplitude and dispersion, phase angle, Cole and impedance geometry, curve shape and coupling, and regional-pattern information. We additionally developed frequency-interval and reliability-weighted interval descriptors to characterize interval-specific variations in multifrequency impedance-magnitude responses and their local agreement with the fitted frequency-response trend. Model performance was assessed using the area under the receiver operating characteristic curve (AUROC) and average precision (AP), together with calibration and threshold-dependent metrics.

Results

Evaluated in 2,745 participants aged 47–90 years from a predominantly older-adult cohort, the ExtraTrees model achieved an AUROC of 0.8336 (95% CI, 0.8138–0.8523) and an AP of 0.6754 (95% CI, 0.6395–0.7092). The full descriptor configuration showed the highest overall discrimination, although the incremental gains associated with the newly developed frequency-interval and reliability-weighted descriptors were modest. These two descriptor groups together accounted for approximately 35.1% of the pooled out-of-fold SHAP contribution, consistent with a complementary rather than dominant predictive role.

Conclusion

This study demonstrates the feasibility of using structured multifrequency segmental BIA-derived descriptors to discriminate previously diagnosed DM status. The newly developed descriptors provided complementary predictive information, although their incremental improvement in discrimination was limited. These findings provide a methodological basis for future evaluation of BIA-assisted screening using contemporaneous blood-test-defined outcomes in appropriately recruited populations.

Schlagwörter

Stichwörter der Autor:innen

bioelectrical impedance analysisdiabetes mellitusdiabetes screeningfrequency-interval descriptormachine learningmultifrequency bioimpedancereliability-weighted descriptor

Autor:innen und Institutionen

  • Life Science Research Division, Korea Institute of Oriental Medicine, Daejeon, Republic of Korea.
  • Gwangju Alzheimer's and Related Dementia Cohort Research Center, Chosun University, Gwangju, Republic of Korea.
  • Department of Biomedical Science, Chosun University, Gwangju, Republic of Korea.
  • Korea Brain Research Institute, Daegu, Republic of Korea.
  • KM Convergence Science, University of Science and Technology, Daejeon, Republic of Korea.

Zitieren

APA

Choi, M., Lee, K. H., & Kim, J. U. (2026). Structured multifrequency segmental bioimpedance descriptors for diabetes screening support. Frontiers in Physiology, 17. https://doi.org/10.3389/fphys.2026.1958735

Vancouver

Choi M, Lee KH, Kim JU. Structured multifrequency segmental bioimpedance descriptors for diabetes screening support. Frontiers in Physiology. 2026;17. doi:10.3389/fphys.2026.1958735

BibTeX
@article{Choi2026,
  author = {Choi, Minho and Lee, Kun Ho and Kim, Jaeuk U},
  title = {Structured multifrequency segmental bioimpedance descriptors for diabetes screening support},
  journal = {Frontiers in Physiology},
  year = {2026},
  volume = {17},
  doi = {10.3389/fphys.2026.1958735}
}
Kostenlos starten →