EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Quantifying changes in triaxial seismocardiography variability due to sub-optimal volume status

Gabriela I Cestero, Zeineb Bouzid, Afra Nawar, Cem O Yaldiz, Demet Tangolar, Zhongjun J Wu, Jin-Oh Hahn, Omer T Inan

Frontiers in Physiology · 18.05.2026 · 17

DOI: 10.3389/fphys.2026.1823345 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Physiology, online erschienen am 18.05.2026. Verfasst von Gabriela I Cestero und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, United States. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Office of Naval Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Hypervolemia (volume overload) and hypovolemia (volume deficit) are sub-optimal blood volume conditions that influence overall circulation and organ function, with substantial shifts posing serious risk of death. In both conditions, the body’s response mechanisms can compensate for sub-optimal volume up to a point at which the cardiovascular system decompensates. Most current methods for assessing blood volume status are either limited to clinical settings or are inaccurate, posing a particular challenge for triaging or monitoring in austere environments. Recent work has aimed at developing novel wearable sensing and machine learning technologies to yield early and accurate signs of sub-optimal volume status prior to decompensation. Seismocardiogram (SCG) signals, representing vibrations of the chest wall due to heartbeat, have been leveraged as a non-invasive and convenient means of extracting cardiac timing representative of sub-optimal volume status. In this work, we aimed to elucidate the changes in morphological variability in the SCG signal in both hypervolemic and hypovolemic conditions. We hypothesized that the variability in the SCG signal would be heightened in decompensated versus compensated states, since the decompensated state would represent hemodynamic conditions that were less stable and thus more variable on a beat-by-beat basis.

Methods

Two datasets were fused for this analysis: 11 heart failure patients with acute decompensation and hypervolemia undergoing vasodilation (thus transitioning to a compensated state), and 15 swine undergoing a volume depletion experiment (hypovolemia). SCG signal consistency, representing the inverse of signal variability, was computed using 60 seconds of data extracted each from the compensation and decompensation periods.

Results

While there was no significant change in signal consistency from compensation to decompensation in the dorso-ventral nor head-to-foot SCG axes for either the hypervolemia or hypovolemia populations, we observed a significant change in signal consistency from compensation to decompensation in the lateral axis for both the hypervolemia (p = 0.042) and hypovolemia (p = 0.012) populations.

Discussion

These results demonstrate an important relationship between compensation status and SCG morphology variability, particularly in the underutilized SCG lateral axis. This paper thus sets a foundation for enabling future algorithms leveraging SCG variability to provide baseline-free estimation capability of sub-optimal volume status in field settings.

Schlagwörter

Stichwörter der Autor:innen

blood volume statushypervolemiahypovolemialateral SCG axisseismocardiogram (SCG)signal consistencysignal variabilitytriaxial SCG

Autor:innen und Institutionen

  • School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, United States.
  • Department of Surgery, University of Maryland School of Medicine, Baltimore, MD, United States.
  • Department of Mechanical Engineering, University of Maryland, College Park, MD, United States.

Förderung

  • Office of Naval Research

Zitieren

APA

Cestero, G. I., Bouzid, Z., Nawar, A., Yaldiz, C. O., Tangolar, D., Wu, Z. J., Hahn, J. O., & Inan, O. T. (2026). Quantifying changes in triaxial seismocardiography variability due to sub-optimal volume status. Frontiers in Physiology, 17. https://doi.org/10.3389/fphys.2026.1823345

Vancouver

Cestero GI, Bouzid Z, Nawar A, Yaldiz CO, Tangolar D, Wu ZJ, et al. Quantifying changes in triaxial seismocardiography variability due to sub-optimal volume status. Frontiers in Physiology. 2026;17. doi:10.3389/fphys.2026.1823345

BibTeX
@article{Cestero2026,
  author = {Cestero, Gabriela I and Bouzid, Zeineb and Nawar, Afra and Yaldiz, Cem O and Tangolar, Demet and Wu, Zhongjun J and Hahn, Jin-Oh and Inan, Omer T},
  title = {Quantifying changes in triaxial seismocardiography variability due to sub-optimal volume status},
  journal = {Frontiers in Physiology},
  year = {2026},
  volume = {17},
  doi = {10.3389/fphys.2026.1823345}
}
Kostenlos starten →