Biomechanical characterization of human lung bullae using uniaxial tensile tests and CT-derived geometry-specific finite element analysis
Frontiers in Physiology · 07.08.2026 · 17
DOI: 10.3389/fphys.2026.1818153 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Physiology, online erschienen am 07.08.2026. Verfasst von Yan Huang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Respiratory and Critical Care Medicine, Air Force Medical Center, PLA, Air Force Medical University, Beijing, China. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Lung bullae are air-filled spaces with thin walls located within the lungs, and they are closely associated with spontaneous pneumothorax. However, quantitative mechanical data on human bullae and subject-specific stress analyses remain sparse.
Methods
We performed uniaxial tensile tests on surgically resected human tissues, including 39 bulla specimens and 34 parenchyma specimens, and fitted the nonlinear stress–strain curves using hyperelastic models. Rupture stress was calculated for specimens that ruptured within the gauge region, comprising 15 bulla specimens and 14 parenchyma specimens. We subsequently constructed 12 CT-derived geometry-specific finite element models of 12 bullae from 10 patients using preoperative CT images, with segmentation performed in Mimics and geometric smoothing performed in Geomagic. High-pressure loading of 110 cmH 2 O was simulated using shell elements for the bulla walls, and the 95th-percentile von Mises stress was used as a robust peak-stress metric.
Results
A second-order Yeoh model best captured the marked strain-stiffening behavior of both tissues. The mean ultimate tensile strength was 2.318 MPa for bulla specimens and 0.390 MPa for parenchyma specimens. In the CT-derived geometry-specific finite element models, the 95th-percentile equivalent von Mises stress ranged from 50.3 to 515.8 kPa, with a median of 106.8 kPa. Elevated stresses were consistently localized to the bulla vertex or apex, defined as the most remote convex peak with the least parenchymal tethering, rather than along the equator. Under the simulated worst-case loading, no case reached the mean experimental ultimate tensile strength of bulla tissue, although one case exceeded the minimum measured bulla ultimate tensile strength of 462 kPa.
Discussion
Human bulla tissue exhibits greater tensile strength than adjacent lung parenchyma but remains vulnerable to elevated local stresses generated by curvature and reduced parenchymal tethering at the apex. CT-derived geometry-specific finite element analysis using hyperelastic constitutive models provides a biomechanical explanation for the clinically observed apical predilection of bulla rupture.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Respiratory and Critical Care Medicine, Air Force Medical Center, PLA, Air Force Medical University, Beijing, China.
- Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing,…
- Department of Respiratory and Critical Care Medicine, Beijing Zhongguancun Hospital, Beijing, China.
- Department of Thoracic Surgery, Air Force Medical Center, PLA, Air Force Medical University, Beijing, China.
- Department of Medical Research, Air Force Medical Center, PLA, Air Force Medical University, Beijing, China.
Zitieren
APA
Huang, Y., Song, J., Fan, H., Zhao, G., Wang, H., Wu, K., Wang, D., Wang, X., & Zou, Z. (2026). Biomechanical characterization of human lung bullae using uniaxial tensile tests and CT-derived geometry-specific finite element analysis. Frontiers in Physiology, 17. https://doi.org/10.3389/fphys.2026.1818153
Vancouver
Huang Y, Song J, Fan H, Zhao G, Wang H, Wu K, et al. Biomechanical characterization of human lung bullae using uniaxial tensile tests and CT-derived geometry-specific finite element analysis. Frontiers in Physiology. 2026;17. doi:10.3389/fphys.2026.1818153
BibTeX
@article{Huang2026,
author = {Huang, Yan and Song, Jianan and Fan, Hong and Zhao, Guangjian and Wang, Huaiyu and Wu, Ke and Wang, Danya and Wang, Xiaofei and Zou, Zhikang},
title = {Biomechanical characterization of human lung bullae using uniaxial tensile tests and CT-derived geometry-specific finite element analysis},
journal = {Frontiers in Physiology},
year = {2026},
volume = {17},
doi = {10.3389/fphys.2026.1818153}
}
EUVIMED