Validity and reliability of a wearable armband for continuous sweat conductivity monitoring during exercise
Frontiers in Physiology · 30.04.2026 · 17
DOI: 10.3389/fphys.2026.1809119 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Physiology, online erschienen am 30.04.2026. Verfasst von Antoine Ferrari und 4 weiteren Autor:innen. Beteiligte Einrichtung: Univ. Lille, Univ. Artois, Univ. Littoral Côte d'Opale, Unité de Recherche Labellisée (ULR) n°7369 - Unité de Recherche Pluridisciplinaire Sport Sant…. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Sweating is essential for thermoregulation during exercise but causes variable losses of water and sodium chloride (NaCl). Field-based methods to assess these losses are limited by sampling errors and the lack of real-time feedback. This study evaluated the validity and reliability of the BeOne armband for continuous measurement of sweat conductivity, used to estimate sweat [NaCl] equivalent in real time.
Methods
Ten armbands were first tested against standard NaCl solutions (5–120 mmol·L −1 ) to assess the validity of the conductivity measurement. Reliability was then examined in sixteen men who completed two 60-min cycling sessions at 150 W in temperate condition (24 ± 1 °C; 50 ± 10% RH) while wearing armbands on both forearms. Outcomes included sweat onset (defined as the time from exercise onset to first detection of sweat conductivity), sweat [NaCl] equivalent drift, and time-normalized [NaCl] equivalent kinetics.
Results
Measured values showed minimal bias (0.28 mmol·L −1 , 95% LoA: –1.21 to 1.77), very low CVs (0.5–2.6%), and excellent inter-device agreement (ICC = 1.00) for conductivity measurements. During exercise, sweat onset did not differ between arms or sessions, but showed moderate within-session (ICC = 0.72) and low between-session reliability (ICC = 0.29), indicating substantial day-to-day variability of this specific index. Drift indices and time-normalized [NaCl] equivalent kinetics revealed a reproducible temporal profile, characterized by an initial peak, a rapid decline, a gradual increase, and a plateau toward the end of exercise.
Conclusion
The BeOne armband demonstrated excellent analytical validity for sweat conductivity measurement and reliable within-session characterization of conductivity-derived sweat electrolyte dynamics. Although conductivity-based [NaCl] equivalents do not represent a laboratory gold standard and remain sensitive to matrix effects and non-specific ionic contributions, this approach appears sufficiently robust for applied sport-science contexts requiring continuous monitoring.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Univ. Lille, Univ. Artois, Univ. Littoral Côte d'Opale, Unité de Recherche Labellisée (ULR) n°7369 - Unité de Recherche Pluridisciplinaire Sport Santé Société (URePSSS), Lille, France.
- Clermont-Auvergne University, Laboratoire des Adaptations Métaboliques è l'Exercice en conditions Physiologiques et Pathologiques (AME2P), Clermont-Ferrand, France.
- Centre d'Investigation Clinique - Innovation Technologique (CIC-IT) (Institut National de la Santé et de la Recherche Médicale (INSERM) 1403), Centre Hospitalier Universitaire de Lille, Lille, France.
Zitieren
APA
Ferrari, A., Ratel, S., Berthoin, S., Garnier, J. P., & Baquet, G. (2026). Validity and reliability of a wearable armband for continuous sweat conductivity monitoring during exercise. Frontiers in Physiology, 17. https://doi.org/10.3389/fphys.2026.1809119
Vancouver
Ferrari A, Ratel S, Berthoin S, Garnier JP, Baquet G. Validity and reliability of a wearable armband for continuous sweat conductivity monitoring during exercise. Frontiers in Physiology. 2026;17. doi:10.3389/fphys.2026.1809119
BibTeX
@article{Ferrari2026,
author = {Ferrari, Antoine and Ratel, Sébastien and Berthoin, Serge and Garnier, Jean-Philippe and Baquet, Georges},
title = {Validity and reliability of a wearable armband for continuous sweat conductivity monitoring during exercise},
journal = {Frontiers in Physiology},
year = {2026},
volume = {17},
doi = {10.3389/fphys.2026.1809119}
}
EUVIMED