EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Responder signatures and predictors of upper- and lower-limb power responsiveness to maximal strength versus plyometric dry-land training in swimmers

Liuxi Yang, Qi Xu, Yu Chen, Jiushu Zhou

Frontiers in Physiology · 04.03.2026 · 17

DOI: 10.3389/fphys.2026.1799253 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Physiology, online erschienen am 04.03.2026. Verfasst von Liuxi Yang und 3 weiteren Autor:innen. Beteiligte Einrichtung: College of Aviation, Civil Aviation Flight University of China, Guanghan, China. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To quantify upper- and lower-limb power responsiveness to maximal strength (MSTG) versus plyometric training (PTG) versus control (CG), and to identify stable responder signatures from the 2D change vector (ΔUpper, ΔLower).

Methods

Twenty-seven university swimmers were randomized to MSTG, PTG, or CG (n = 9 each) for 6 weeks with testing at Pre, Mid, and Post. Upper- and lower-limb power constructs were derived via baseline-fitted PCA from bench press power plus medicine-ball throw and from CMJ, SJ, DJ, plus SLJ, respectively; responsiveness was Post–Pre. Group contrasts used permutation tests with Holm adjustment and bootstrap confidence intervals. Responder signatures were identified by Ward clustering with cluster-number selection and bootstrap stability.

Results

ΔUpper was 0.962 ± 0.129 (MSTG), 0.762 ± 0.218 (PTG), and 0.332 ± 0.058 (CG); MSTG–PTG mean difference was 0.200 (95% CI [0.047, 0.356], p = 0.030, g = 1.065), and both exceeded CG (p < 0.001). ΔLower was 0.822 ± 0.125 (MSTG), 0.758 ± 0.150 (PTG), and 0.388 ± 0.059 (CG); MSTG–PTG was 0.065 (p = 0.331), while both exceeded CG (p < 0.001). Clustering selected k = 2 (silhouette 0.608) with high stability (ARI 0.840 [0.591, 1.000]) and strong group association (χ 2 = 18.900, p < 0.001).

Conclusion

In this sample, MSTG elicited larger upper-limb responsiveness than PTG, while both approaches improved upper- and lower-limb constructs versus CG, and responder signatures were stable and strongly aligned with training modality. In exploratory models within our sample, short-duration intervention, training allocation (stimulus) dominated modeled responsiveness and baseline sprint performance showed an inverse association with high-responder membership, patterns consistent with short-block trainability/ceiling effects, therefore these predictive findings should be interpreted as context-specific and not generalized beyond similar swimmer levels and intervention doses.

Schlagwörter

Stichwörter der Autor:innen

dry-land traininghierarchicalclusteringinter-individual variabilityneuromuscular powerresponder classificationstrengthand conditioningswimming performance

Autor:innen und Institutionen

  • College of Aviation, Civil Aviation Flight University of China, Guanghan, China.
  • Gdansk University of Physical Education and Sport, Gdańsk, Poland.
  • School of Physical Education, Chengdu Sport University, Chengdu, China.

Zitieren

APA

Yang, L., Xu, Q., Chen, Y., & Zhou, J. (2026). Responder signatures and predictors of upper- and lower-limb power responsiveness to maximal strength versus plyometric dry-land training in swimmers. Frontiers in Physiology, 17. https://doi.org/10.3389/fphys.2026.1799253

Vancouver

Yang L, Xu Q, Chen Y, Zhou J. Responder signatures and predictors of upper- and lower-limb power responsiveness to maximal strength versus plyometric dry-land training in swimmers. Frontiers in Physiology. 2026;17. doi:10.3389/fphys.2026.1799253

BibTeX
@article{Yang2026,
  author = {Yang, Liuxi and Xu, Qi and Chen, Yu and Zhou, Jiushu},
  title = {Responder signatures and predictors of upper- and lower-limb power responsiveness to maximal strength versus plyometric dry-land training in swimmers},
  journal = {Frontiers in Physiology},
  year = {2026},
  volume = {17},
  doi = {10.3389/fphys.2026.1799253}
}
Kostenlos starten →