EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A chamber study of respiratory and autonomic responses to hydrotreated vegetable oil exhaust using ECG-derived respiration

Mostafa Abdollahpur, Louise Gren, Katrin Dierschke, Leo Stockfelt, Aneta Wierzbicka, Frida Sandberg

Frontiers in Physiology · 03.06.2026 · 17

DOI: 10.3389/fphys.2026.1710755 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Physiology, online erschienen am 03.06.2026. Verfasst von Mostafa Abdollahpur und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Lund University, Lund, Sweden. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Air pollution is a major public health concern, contributing to cardiovascular and respiratory diseases. One of the main pathways by which air pollution affects cardiovascular health is through dysregulation of the autonomic nervous system (ANS), which impairs cardiac control. Hydrotreated vegetable oil (HVO) is a renewable fuel with unknown toxicity in comparison to conventional diesel, and the effects of HVO exhaust on autonomic and respiratory regulation remain unclear.

Objective

This study investigates the physiological responses to HVO exhaust exposure by assessing heart rate variability (HRV), ECG-derived respiration (EDR) and cardiorespiratory coupling (CRC).

Methods

A controlled exposure study was conducted with 19 healthy volunteers (10 males, 9 females, aged 20–55) who underwent four different exposure scenarios in a randomized, double-blind design: filtered air, filtered air with NaCl particles, HVO exhaust with an aftertreatment system, and HVO exhaust without aftertreatment. ECG signals were continuously recorded, and HRV, EDR, and CRC features were extracted. A linear mixed model was used to assess time- and exposure-dependent changes.

Results

No statistically significant differences in HRV, EDR, or CRC features were found between exposure scenarios.

Conclusion

In this study, short-term exposure to HVO exhaust, corresponding to EU OELs for one workday, was not associated with statistically significant changes in the ECG-derived autonomic, respiratory, or cardiorespiratory-coupling markers assessed in healthy volunteers at the studied pollutant concentrations.

Schlagwörter

Stichwörter der Autor:innen

ECG-derived respiration (EDR)air pollutioncardiorespiratory coupling (CRC)heart rate variability (HRV)hydrotreated vegetable oil (HVO)mutual information (MUI)

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Lund University, Lund, Sweden.
  • Ergonomics and Aerosol Technology, Lund University, Lund, Sweden.
  • Occupational and Environmental Medicine, Region Skåne, Lund, Sweden.
  • Department of Occupational and Environmental Medicine, Sahlgrenska University Hospital, Gothenburg, Sweden.
  • Occupational and Environmental Medicine, School of Public Health and Community Medicine, Institute of Medicine, University of Gothenburg, Gothenburg, Sweden.

Zitieren

APA

Abdollahpur, M., Gren, L., Dierschke, K., Stockfelt, L., Wierzbicka, A., & Sandberg, F. (2026). A chamber study of respiratory and autonomic responses to hydrotreated vegetable oil exhaust using ECG-derived respiration. Frontiers in Physiology, 17. https://doi.org/10.3389/fphys.2026.1710755

Vancouver

Abdollahpur M, Gren L, Dierschke K, Stockfelt L, Wierzbicka A, Sandberg F. A chamber study of respiratory and autonomic responses to hydrotreated vegetable oil exhaust using ECG-derived respiration. Frontiers in Physiology. 2026;17. doi:10.3389/fphys.2026.1710755

BibTeX
@article{Abdollahpur2026,
  author = {Abdollahpur, Mostafa and Gren, Louise and Dierschke, Katrin and Stockfelt, Leo and Wierzbicka, Aneta and Sandberg, Frida},
  title = {A chamber study of respiratory and autonomic responses to hydrotreated vegetable oil exhaust using ECG-derived respiration},
  journal = {Frontiers in Physiology},
  year = {2026},
  volume = {17},
  doi = {10.3389/fphys.2026.1710755}
}
Kostenlos starten →