Pulse rate variability is not the same as heart rate variability: findings from a large, diverse clinical population study
Frontiers in Physiology · 30.07.2025 · 16
DOI: 10.3389/fphys.2025.1630032 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Physiology, online erschienen am 30.07.2025. Verfasst von Allen B Kantrowitz und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Mount Sinai Medical Center, Miami Beach, FL, United States. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Scientists and consumer products are increasingly employing light-based photoplethysmography (PPG) instead of electrocardiography (ECG) assuming it accurately quantifies heart rate variability (HRV). Recent studies, however, have demonstrated that pulse rate variability (PRV) derived from PPG is not equivalent to HRV-derived from ECG. This study investigated the agreement between PPG-PRV and ECG-HRV in a beat-to-beat analysis in 931 adults recruited from a tertiary academic medical center in the southeastern United States.
Methods
Participants wore two (chest and bicep) Warfighter Monitor™ devices (Tiger Tech Solutions, Inc.). Heart rate (HR), pulse rate (PR) and three time-domain indices for PPG-PRV and ECG-HRV were measured. ECG-derived RR and noise-filtered NN intervals were extracted to compute HR, SDNN (standard deviation of NN intervals), rMSSD (root mean square of successive differences), and pNN50 (percentage of successive NN intervals differing by >50 ms). PPG-derived pulse-wave peaks were detected to calculate corresponding PR/PRV metrics. Pearson correlation, Bland–Altman, and one-way ANOVA analyses assessed linear association, bias, and mean differences across select chronic diseases.
Results
Significant disagreement and differences were observed between ECG-HRV and PPG-PRV (p < 0.001 for all). For rMSSD: cardiovascular: 3.04 ms, 95% CI: 1.33, 4.75, endocrine : 2.85 ms, 95% CI: 0.52, 5.18, and neurological: 4.39 ms, 95% CI: 1.39, 7.39). For SDNN: cardiovascular: 8.50 ms, 95% CI: 5.25, 11.74, endocrine: 8.43 ms, 95% CI: 3.97, 12.90, neurological: 11.84 ms, 95% CI: 6.02, 17.67, and respiratory: 7.23 ms, 95% CI: 1.83, 12.62). For pNN50: cardiovascular: 2.48%, 95% CI: 1.67, 3.3, endocrine : 2.21% 95% CI: 1.12, 3.29, neurological: 2.91%, 95% CI: 1.25, 4.32, and respiratory: 1.46%, 95% CI: 0.15, 2.77).
Discussion
PPG-PRV is a poor surrogate for ECG- HRV as it significantly underestimated SDNN, rMSSD, and pNN50 across select chronic diseases. Given the widespread use of PPG-based devices and ubiquitous, incorrect assumption that PRV accurately reflects HRV, researchers, clinicians, and manufacturers must clearly distinguish between PRV and HRV in studies and product claims.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, Mount Sinai Medical Center, Miami Beach, FL, United States.
- Department of Surgery, Mount Sinai Medical Center, Miami Beach, FL, United States.
- Department of General Surgery, College of Medicine, University of Florida, Gainsville, FL, United States.
- Department of Pulmonology, Brooke Army Medical Center, Fort Sam Houston, TX, United States.
- San Antonio Uniformed Services Health Education Consortium, Uniformed Services University, San Antonio, TX, United States.
- Tiger Tech Solutions, Inc., Miami, FL, United States.
Zitieren
APA
Kantrowitz, A. B., Ben-David, K., Morris, M., Wittels, H. L., Wishon, M. J., McDonald, S. M., Renaghan, E. J., Feigenbaum, L. A., & Wittels, S. H. (2025). Pulse rate variability is not the same as heart rate variability: findings from a large, diverse clinical population study. Frontiers in Physiology, 16. https://doi.org/10.3389/fphys.2025.1630032
Vancouver
Kantrowitz AB, Ben-David K, Morris M, Wittels HL, Wishon MJ, McDonald SM, et al. Pulse rate variability is not the same as heart rate variability: findings from a large, diverse clinical population study. Frontiers in Physiology. 2025;16. doi:10.3389/fphys.2025.1630032
BibTeX
@article{Kantrowitz2025,
author = {Kantrowitz, Allen B and Ben-David, Kfir and Morris, Michael and Wittels, Harrison L and Wishon, Michael J and McDonald, Samantha M and Renaghan, Eric J and Feigenbaum, Luis A and Wittels, S Howard},
title = {Pulse rate variability is not the same as heart rate variability: findings from a large, diverse clinical population study},
journal = {Frontiers in Physiology},
year = {2025},
volume = {16},
doi = {10.3389/fphys.2025.1630032}
}
EUVIMED