Reliability and validity of a non-linear index of heart rate variability to determine intensity thresholds
Frontiers in Physiology · 05.02.2024 · 15
DOI: 10.3389/fphys.2024.1329360 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Physiology, online erschienen am 05.02.2024. Verfasst von Noemí Sempere-Ruiz und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sport Sciences, Sport Research Centre, Miguel Hernandez University, Elche, Spain. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Exercise intensity distribution is crucial for exercise individualization, prescription, and monitoring. As traditional methods to determine intensity thresholds present limitations, heart rate variability (HRV) using DFA a1 has been proposed as a biomarker for exercise intensity distribution. This index has been associated with ventilatory and lactate thresholds in previous literature. This study aims to assess DFA a1’s reliability and validity in determining intensity thresholds during an incremental cycling test in untrained healthy adults. Sixteen volunteers (13 males and 3 females) performed two identical incremental cycling stage tests at least 1 week apart. First and second ventilatory thresholds, lactate thresholds, and HRV thresholds (DFA a1 values of 0.75 and 0.5 for HRVT1 and HRVT2, respectively) were determined in heart rate (HR), relative oxygen uptake (VO 2 rel), and power output (PO) values for both tests. We used intraclass correlation coefficient (ICC), change in mean, and typical error for the reliability analysis, and paired t-tests, correlation coefficients, ICC, and Bland-Altman analysis to assess the agreement between methods. Regarding reliability, HRV thresholds showed the best ICCs when measured in PO (HRVT1: ICC = .87; HRVT2: ICC = .97), comparable to ventilatory and lactate methods. HRVT1 showed the strongest agreement with LA 2.5 in PO ( p = 0.09, r = .93, ICC = .93, bias = 9.9 ± 21.1), while HRVT2 reported it with VT2 in PO ( p = 0.367, r = .92, ICC = .92, bias = 5.3 ± 21.9). DFA a1 method using 0.75 and 0.5 values is reliable and valid to determine HRV thresholds in this population, especially in PO values.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Sport Sciences, Sport Research Centre, Miguel Hernandez University, Elche, Spain.
- Alicante Institute for Health and Biomedical Research (ISABIAL), Alicante, Spain.
Zitieren
APA
Sempere-Ruiz, N., Sarabia, J. M., Baladzhaeva, S., & Moya-Ramón, M. (2024). Reliability and validity of a non-linear index of heart rate variability to determine intensity thresholds. Frontiers in Physiology, 15. https://doi.org/10.3389/fphys.2024.1329360
Vancouver
Sempere-Ruiz N, Sarabia JM, Baladzhaeva S, Moya-Ramón M. Reliability and validity of a non-linear index of heart rate variability to determine intensity thresholds. Frontiers in Physiology. 2024;15. doi:10.3389/fphys.2024.1329360
BibTeX
@article{SempereRuiz2024,
author = {Sempere-Ruiz, Noemí and Sarabia, José Manuel and Baladzhaeva, Sabina and Moya-Ramón, Manuel},
title = {Reliability and validity of a non-linear index of heart rate variability to determine intensity thresholds},
journal = {Frontiers in Physiology},
year = {2024},
volume = {15},
doi = {10.3389/fphys.2024.1329360}
}
EUVIMED