EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Feasibility of high-resolution perfusion imaging using arterial spin labeling MRI at 3 Tesla

Sriranga Kashyap, Ícaro Agenor Ferreira Oliveira, Kâmil Uludağ

Frontiers in Physiology · 03.01.2024 · 14

DOI: 10.3389/fphys.2023.1271254 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Physiology, online erschienen am 03.01.2024. Verfasst von Sriranga Kashyap und 2 weiteren Autor:innen. Beteiligte Einrichtung: Krembil Brain Institute, University Health Network, Toronto, ON, Canada. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institute for Basic Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cerebral blood flow (CBF) is a critical physiological parameter of brain health, and it can be non-invasively measured with arterial spin labeling (ASL) MRI. In this study, we evaluated and optimized whole-brain, high-resolution ASL as an alternative to the low-resolution ASL employed in the routine assessment of CBF in both healthy participants and patients. Two high-resolution protocols (i.e., pCASL and FAIR-Q2TIPS (PASL) with 2 mm isotropic voxels) were compared to a default clinical pCASL protocol (3.4 × 3.4 × 4 mm 3 ), all of whom had an acquisition time of ≈ 5 min. We assessed the impact of high-resolution acquisition on reducing partial voluming and improving sensitivity to the perfusion signal, and evaluated the effectiveness of z-deblurring on the ASL data. We compared the quality of whole-brain ASL acquired using three available head coils with differing number of receive channels (i.e., 20, 32, and 64ch). We found that using higher coil counts (32 and 64ch coils as compared to 20ch) offers improved signal-to-noise ratio (SNR) and acceleration capabilities that are beneficial for ASL imaging at 3 Tesla (3 T). The inherent reduction in partial voluming effects with higher resolution acquisitions improves the resolving power of perfusion without impacting the sensitivity. In conclusion, our results suggest that high-resolution ASL (2 to 2.5 mm isotropic voxels) has the potential to become a new standard for perfusion imaging at 3 T and increase its adoption into clinical research and cognitive neuroscience applications.

Schlagwörter

Stichwörter der Autor:innen

3 TeslaRF coilarterial spin labelingbrain perfusionhigh spatial resolutionneuroimaging frontiers

Autor:innen und Institutionen

  • Krembil Brain Institute, University Health Network, Toronto, ON, Canada.
  • Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada.
  • Center for Neuroscience Imaging Research, Institute for Basic Science, Suwon, Republic of Korea.
  • Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.
  • Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada.

Förderung

  • Institute for Basic Science

Zitieren

APA

Kashyap, S., Oliveira, Í. A. F., & Uludağ, K. (2024). Feasibility of high-resolution perfusion imaging using arterial spin labeling MRI at 3 Tesla. Frontiers in Physiology, 14. https://doi.org/10.3389/fphys.2023.1271254

Vancouver

Kashyap S, Oliveira ÍAF, Uludağ K. Feasibility of high-resolution perfusion imaging using arterial spin labeling MRI at 3 Tesla. Frontiers in Physiology. 2024;14. doi:10.3389/fphys.2023.1271254

BibTeX
@article{Kashyap2024,
  author = {Kashyap, Sriranga and Oliveira, Ícaro Agenor Ferreira and Uludağ, Kâmil},
  title = {Feasibility of high-resolution perfusion imaging using arterial spin labeling MRI at 3 Tesla},
  journal = {Frontiers in Physiology},
  year = {2024},
  volume = {14},
  doi = {10.3389/fphys.2023.1271254}
}