EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Imputation models and error analysis for phase contrast MR cerebral blood flow measurements

Payal Shah, Eamon Doyle, John C Wood, Matthew T Borzage

Frontiers in Physiology · 20.02.2023 · 14

DOI: 10.3389/fphys.2023.1096297 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Physiology, online erschienen am 20.02.2023. Verfasst von Payal Shah und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Department of Pediatrics, Children's Hospital Los Angeles, Los Angeles, CA, United States. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHLBI NIH HHS, NIA NIH HHS, National Heart, Lung, and Blood Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cerebral blood flow (CBF) supports brain metabolism. Diseases impair CBF, and pharmacological agents modulate CBF. Many techniques measure CBF, but phase contrast (PC) MR imaging through the four arteries supplying the brain is rapid and robust. However, technician error, patient motion, or tortuous vessels degrade quality of the measurements of the internal carotid (ICA) or vertebral (VA) arteries. We hypothesized that total CBF could be imputed from measurements in subsets of these 4 feeding vessels without excessive penalties in accuracy. We analyzed PC MR imaging from 129 patients, artificially excluded 1 or more vessels to simulate degraded imaging quality, and developed models of imputation for the missing data. Our models performed well when at least one ICA was measured, and resulted in R 2 values of 0.998–0.990, normalized root mean squared error values of 0.044–0.105, and intra-class correlation coefficient of 0.982–0.935. Thus, these models were comparable or superior to the test-retest variability in CBF measured by PC MR imaging. Our imputation models allow retrospective correction for corrupted blood vessel measurements when measuring CBF and guide prospective CBF acquisitions.

Schlagwörter

Stichwörter der Autor:innen

cerebral blood flow (CBF)internal carotid artery (ICA)magnetic resonance imaging (MRI)phase contrast (PC)vertebral artery

Autor:innen und Institutionen

  • Division of Cardiology, Department of Pediatrics, Children's Hospital Los Angeles, Los Angeles, CA, United States.
  • Department of Radiology, Children's Hospital Los Angeles, Los Angeles, CA, United States.
  • Division of Neonatology, Department of Pediatrics, Children's Hospital Los Angeles, Keck School of Medicine, Fetal and Neonatal Institute, University of Southern California, Los Angeles, CA, United States.

Förderung

  • NHLBI NIH HHS
  • NIA NIH HHS
  • National Heart, Lung, and Blood Institute

Zitieren

APA

Shah, P., Doyle, E., Wood, J. C., & Borzage, M. T. (2023). Imputation models and error analysis for phase contrast MR cerebral blood flow measurements. Frontiers in Physiology, 14. https://doi.org/10.3389/fphys.2023.1096297

Vancouver

Shah P, Doyle E, Wood JC, Borzage MT. Imputation models and error analysis for phase contrast MR cerebral blood flow measurements. Frontiers in Physiology. 2023;14. doi:10.3389/fphys.2023.1096297

BibTeX
@article{Shah2023,
  author = {Shah, Payal and Doyle, Eamon and Wood, John C and Borzage, Matthew T},
  title = {Imputation models and error analysis for phase contrast MR cerebral blood flow measurements},
  journal = {Frontiers in Physiology},
  year = {2023},
  volume = {14},
  doi = {10.3389/fphys.2023.1096297}
}
Kostenlos starten →