EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Software-defined lock-in detection for photoacoustic gas sensing

Chenglong Wang, Yanan Su, Chaofeng Sun, Yaoxin Wang, Jintao Wu, Chunhong Zhao, Shurong Guo, Ruyue Cui, Lei Dong, Hongpeng Wu

Frontiers in Physics · 02.11.2026 · 14

DOI: 10.3389/fphy.2026.2009327 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Physics, online erschienen am 02.11.2026. Verfasst von Chenglong Wang und 9 weiteren Autor:innen. Die Arbeit nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Photoacoustic spectroscopy enables compact and selective gas sensing, but its weak acoustic signals require effective phase-sensitive detection. Conventional PAS systems commonly rely on standalone lock-in amplifiers, which separate the demodulation function from excitation generation, sensor control, and data management, limiting system integration and reconfigurability.

Methods

This work presents a real-time software-defined digital lock-in amplifier that unifies modulation-waveform generation, phase-coherent signal acquisition, quadrature demodulation, configurable filtering, real-time visualization, and data logging within a single LabVIEW application interfaced with a National Instruments USB-6361 data-acquisition module. The S-DLIA was integrated into a CO 2 PAS platform employing a distributed-feedback diode laser at 4992.5157 cm -1 , a differential resonant photoacoustic cell, and second-harmonic wavelength modulation. It was benchmarked against a commercial SR830 lock-in amplifier processing the same photoacoustic signal under matched conditions.

Results

The sensor responded linearly to CO 2 concentrations from 100 to 1,000 ppm ( R 2 = 0.999). Allan deviation analysis at an integration time of 220 s yielded minimum detection limits of 0.505 ppm for the S-DLIA and 8.909 ppm for the SR830 under the tested configuration, corresponding to a 17.6-fold lower detection limit compared with the SR830. Continuous operation over 24 h at a fixed laboratory location tracked indoor CO 2 variations without apparent drift.

Discussion

These results validate the S-DLIA as a reconfigurable and flexible alternative to dedicated lock-in instruments in PAS, demonstrating the potential of software-defined synchronous detection for integrated gas-sensing systems.

Zitieren

APA

Wang, C., Su, Y., Sun, C., Wang, Y., Wu, J., Zhao, C., Guo, S., Cui, R., Dong, L., & Wu, H. (2026). Software-defined lock-in detection for photoacoustic gas sensing. Frontiers in Physics, 14. https://doi.org/10.3389/fphy.2026.2009327

Vancouver

Wang C, Su Y, Sun C, Wang Y, Wu J, Zhao C, et al. Software-defined lock-in detection for photoacoustic gas sensing. Frontiers in Physics. 2026;14. doi:10.3389/fphy.2026.2009327

BibTeX
@article{Wang2026,
  author = {Wang, Chenglong and Su, Yanan and Sun, Chaofeng and Wang, Yaoxin and Wu, Jintao and Zhao, Chunhong and Guo, Shurong and Cui, Ruyue and Dong, Lei and Wu, Hongpeng},
  title = {Software-defined lock-in detection for photoacoustic gas sensing},
  journal = {Frontiers in Physics},
  year = {2026},
  volume = {14},
  doi = {10.3389/fphy.2026.2009327}
}
Kostenlos starten →