EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Multi-band localized surface plasmon enhanced terahertz biosensor chip with electrostatic and acousto-optic active tuning

Xiaoguang Xu, Qiang Zhang, Haibo Zhou, Dong Zhang, Yi Zhou, Xu Li

Frontiers in Physics · 10.11.2026 · 14

DOI: 10.3389/fphy.2026.1994371 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Physics, online erschienen am 10.11.2026. Verfasst von Xiaoguang Xu und 5 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Terahertz (THz) biosensing can read biomolecular vibrations without labels, yet two practical problems limit its sensitivity: sub-wavelength biological samples interact only weakly with the radiation, and 1/f noise dominates slow readouts.

Methods

We propose a multi-band localized surface plasmon (LSP)-enhanced THz biosensor chip in which a gold metasurface of nine spectrally isolated cross-resonator sub-arrays sustains LSP resonances at 0.1–0.9 THz, concentrating the field in deep-sub-wavelength hot spots at the resonator arm ends and gaps. An in-plane electrostatic bias tunes any resonance by up to 7.5%, and a 60 MHz surface acoustic wave (SAW) modulates the transmitted signal so that lock-in readout can reject roughly 15 dB of low-frequency noise. Coupled-mode theory was used to compute the transmission, near-field enhancement, tuning, and detection-limit improvement; the same array supports two readout modes, broadband THz time-domain spectroscopy (THz-TDS) and direct THz-induced micro-current detection.

Results

The calculations give a field enhancement of 17–33×, per-band redshifts of 1.6–2.8% that vary by band and can be read as a nine-point spectral pattern against calibration spectra, and a 39.6–45.4 dB improvement in detection limit over bare THz-TDS, corresponding to a 95–186× reduction in the minimum detectable amplitude.

Discussion

The intended analytes are proteins, sugars, antibiotics, and bacteria, measured as dried surface films or thin (≤5 µm) aqueous layers. The layout uses standard microfabrication and no cryogenics, providing a practical route toward high-sensitivity, multi-band label-free THz biodetection.

Zitieren

APA

Xu, X., Zhang, Q., Zhou, H., Zhang, D., Zhou, Y., & Li, X. (2026). Multi-band localized surface plasmon enhanced terahertz biosensor chip with electrostatic and acousto-optic active tuning. Frontiers in Physics, 14. https://doi.org/10.3389/fphy.2026.1994371

Vancouver

Xu X, Zhang Q, Zhou H, Zhang D, Zhou Y, Li X. Multi-band localized surface plasmon enhanced terahertz biosensor chip with electrostatic and acousto-optic active tuning. Frontiers in Physics. 2026;14. doi:10.3389/fphy.2026.1994371

BibTeX
@article{Xu2026,
  author = {Xu, Xiaoguang and Zhang, Qiang and Zhou, Haibo and Zhang, Dong and Zhou, Yi and Li, Xu},
  title = {Multi-band localized surface plasmon enhanced terahertz biosensor chip with electrostatic and acousto-optic active tuning},
  journal = {Frontiers in Physics},
  year = {2026},
  volume = {14},
  doi = {10.3389/fphy.2026.1994371}
}
Kostenlos starten →