Introduction

The terahertz (THz) band enables non-destructive molecular sensing of controlled substances including amphetamine, cocaine, and ketamine, which possess characteristic THz absorption fingerprints. Existing THz photonic crystal fiber (PCF) biosensors frequently achieve relative sensitivity below 80% with high confinement losses, limiting their practical utility.

Methods

A seven-hexagon void-core photonic crystal fiber biosensor (VCPCFB) was designed in a Zeonex substrate (n = 1.53, α = 0.2 cm −1 ) with a 10 μm pitch and 700 μm core radius. Full-vector finite element method (FEM) simulations were performed in COMSOL Multiphysics over 1.0–3.0 THz with perfectly matched layer boundaries. Amphetamine (n = 1.518), cocaine (n = 1.5022), and ketamine (n = 1.562) were represented as frequency-independent homogeneous bulk analytes fully occupying the hollow core.

Results

At 3 THz, relative sensitivity reaches 99.95% for ketamine, 99.84% for amphetamine, and 99.78% for cocaine. Power confinement exceeds 99% for all analytes. Effective material loss reduces to 5.98 × 10 −4 cm −1 for ketamine. Confinement loss approaches 0 cm⁻¹ for ketamine at the operating point. Chromatic dispersion ranges between +0.097 and +0.149 ps/THz/cm at 3 THz, with group velocity dispersion below 0.05 ps²/cm. The nonlinear coefficient ranges from 1.87–1.91 × 10 −3 W −1 cm −1 and self-phase modulation length exceeds 5 × 10 5 cm at 1 mW. Differential group delay enables ketamine–cocaine separation over ~16.1 cm fiber lengths. Beat lengths exceed 2,353 cm, confirming negligible polarization evolution.

Discussion

The proposed seven-hexagon void-core architecture simultaneously achieves near-unity relative sensitivity, ultra-low propagation loss, flat dispersion, negligible nonlinear effects, and excellent fabrication tolerance. Pitch is identified as the most sensitive structural parameter. The design outperforms all previously reported THz PCF biosensors included in the benchmark comparison, with the proposed maximum sensitivity of 99.95% exceeding the nearest competitor by 7.75 percentage points.

Zitieren

APA

Abdulrazaq, K. U., & Wekalao, J. (2026). High-performance void-core photonic crystal fiber biosensor for terahertz detection of illicit drugs. Frontiers in Physics, 14. https://doi.org/10.3389/fphy.2026.1896756

Vancouver

Abdulrazaq KU, Wekalao J. High-performance void-core photonic crystal fiber biosensor for terahertz detection of illicit drugs. Frontiers in Physics. 2026;14. doi:10.3389/fphy.2026.1896756

BibTeX
@article{Abdulrazaq2026,
  author = {Abdulrazaq, Kabeer Usman and Wekalao, Jacob},
  title = {High-performance void-core photonic crystal fiber biosensor for terahertz detection of illicit drugs},
  journal = {Frontiers in Physics},
  year = {2026},
  volume = {14},
  doi = {10.3389/fphy.2026.1896756}
}
Kostenlos starten →