A resonant photoacoustic spectroscopy sensor for ppb-level detection of acetylene employing a 1.53 μm laser diode
Frontiers in Physics · 05.03.2026 · 14
DOI: 10.3389/fphy.2026.1791434 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Physics, online erschienen am 05.03.2026. Verfasst von Lei Peng und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
A compact and highly sensitive photoacoustic spectroscopy (PAS) sensor for dissolved acetylene (C 2 H 2 ) detection was developed for transformer fault diagnosis applications. A 1.53 μm distributed-feedback (DFB) diode laser targeting the ν 1 + ν 3 absorption line of acetylene at ∼1530.37 nm was employed, benefiting from strong line intensity and high transparency of transformer oil in the near-infrared region. Wavelength modulation spectroscopy combined with second-harmonic ( 2f ) demodulation was implemented, and the modulation depth was optimized to 120 mVpp to achieve the maximum normalized 2f signal. A high-Q resonant photoacoustic cell was designed to enhance the acoustic response and improve the signal-to-noise ratio. Experimental results demonstrated excellent linearity ( R 2 = 0.999) over the concentration range of 200–1,000 ppm. For a standard 100 ppm C 2 H 2 /N 2 mixture, a peak 2f signal amplitude of 5.4 × 10 −5 V was obtained, with a noise level of 4.05 × 10 −7 V (1σ). Allan deviation analysis further confirmed the outstanding long-term stability of the system, achieving a detection sensitivity of 0.75 ppm at 1 s and a minimum detection limit of 50 ppb at an integration time of 3,200 s. These results indicate that the proposed PAS sensor enables accurate, real-time, and trace-level acetylene detection, demonstrating strong potential for dissolved gas analysis in transformer oil and early warning of incipient arcing faults.
Zitieren
APA
Peng, L., Qian, Y., Zhao, Y., Wang, Q., Zhao, Y., & Fu, Q. (2026). A resonant photoacoustic spectroscopy sensor for ppb-level detection of acetylene employing a 1.53 μm laser diode. Frontiers in Physics, 14. https://doi.org/10.3389/fphy.2026.1791434
Vancouver
Peng L, Qian Y, Zhao Y, Wang Q, Zhao Y, Fu Q. A resonant photoacoustic spectroscopy sensor for ppb-level detection of acetylene employing a 1.53 μm laser diode. Frontiers in Physics. 2026;14. doi:10.3389/fphy.2026.1791434
BibTeX
@article{Peng2026,
author = {Peng, Lei and Qian, Yihua and Zhao, Yaohong and Wang, Qing and Zhao, Yifeng and Fu, Qiang},
title = {A resonant photoacoustic spectroscopy sensor for ppb-level detection of acetylene employing a 1.53 μm laser diode},
journal = {Frontiers in Physics},
year = {2026},
volume = {14},
doi = {10.3389/fphy.2026.1791434}
}
EUVIMED