EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Underwater temperature and pressure monitoring for deep-sea SCUBA divers using optical techniques

Jawad Mirza, Firdos Kanwal, Umair Ahmad Salaria, Salman Ghafoor, Imran Aziz, Ahmad Atieh, Ahmad Almogren, Anwar Ul Haq, Benish Kanwal

Frontiers in Physics · 29.07.2024 · 12

DOI: 10.3389/fphy.2024.1417293 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Physics, online erschienen am 29.07.2024. Verfasst von Jawad Mirza und 8 weiteren Autor:innen. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The safety of SCUBA divers remains at high risk in deep-sea owing to multiple factors such as dangerous surrounding, rely upon technical equipment necessary for life support, decreased underwater navigation, and communication infrastructure. Gradual decrease and increase in water temperature and pressure corresponding to depth are among the most common problems that cause most of the fatalities in deep-sea diving. Therefore, different gadgets for accurate measurement of vital parameters, reliable navigation, and seamless communication are of prime importance. In this paper, we propose an all-optical technique for local and remote monitoring of underwater temperature and pressure for deep-sea SCUBA divers based on fiber Bragg grating (FBG) sensors and underwater optical communication-single mode fiber (UWOC-SMF) integrated transmission system. The proposed technique is implemented using two FBG temperature and pressure sensors fixed over diver’s suit and UWOC-SMF integrated transmission system for simultaneous local and remote monitoring of underwater temperature and pressure. Remote monitoring of underwater temperature and pressure is achieved at ship station through a remotely operated underwater vehicle (ROV) and UWOC-SMF integrated transmission system by means of shifts in the original Bragg wavelengths of sensors due to temperature and pressure variations. The performance of the sensors is analyzed for pressure and temperature in the range of 0 to 6.4 MPa ( ≈ 0 to 655 m H 2 O ) and 40 to −2 °C , respectively corresponding to different depths. The results show that the proposed technique can work well in the deep ocean over a range of pressures and temperatures of 0–7 MPa and 40 to −2 °C while achieving a temperature sensitivity of 4.3 p.m./ ° C and a pressure sensitivity of 30.5 p.m./MPa. Clear spectra of reflected signals from FBG sensors at ship station are achieved after signal transmission over UWOC-SMF hybrid link.

Zitieren

APA

Mirza, J., Kanwal, F., Salaria, U. A., Ghafoor, S., Aziz, I., Atieh, A., Almogren, A., Haq, A. U., & Kanwal, B. (2024). Underwater temperature and pressure monitoring for deep-sea SCUBA divers using optical techniques. Frontiers in Physics, 12. https://doi.org/10.3389/fphy.2024.1417293

Vancouver

Mirza J, Kanwal F, Salaria UA, Ghafoor S, Aziz I, Atieh A, et al. Underwater temperature and pressure monitoring for deep-sea SCUBA divers using optical techniques. Frontiers in Physics. 2024;12. doi:10.3389/fphy.2024.1417293

BibTeX
@article{Mirza2024,
  author = {Mirza, Jawad and Kanwal, Firdos and Salaria, Umair Ahmad and Ghafoor, Salman and Aziz, Imran and Atieh, Ahmad and Almogren, Ahmad and Haq, Anwar Ul and Kanwal, Benish},
  title = {Underwater temperature and pressure monitoring for deep-sea SCUBA divers using optical techniques},
  journal = {Frontiers in Physics},
  year = {2024},
  volume = {12},
  doi = {10.3389/fphy.2024.1417293}
}