EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Cavity ring-down spectroscopy with a laser frequency stabilized and locked to a reference target gas absorption for drift-free accurate gas sensing measurements

Ying Liu, Yabai He, Mai Hu, Bing Chen, Zhenyu Xu, Lu Yao, Xingping Wang, Ruifeng Kan

Frontiers in Physics · 19.07.2023 · 11

DOI: 10.3389/fphy.2023.1238869 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Physics, online erschienen am 19.07.2023. Verfasst von Ying Liu und 7 weiteren Autor:innen. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Youth Innovation Promotion Association of the Chinese Academy of Sciences.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A new gas sensor system with fast response and ultra-high sensitivity has been developed based on a combination of frequency modulation spectroscopy (FMS) and cavity ring-down spectroscopy (CRDS). The system consisted of two distributed feedback laser diodes (DFB-LDs) emitting at frequencies 6251.761 cm -1 (Laser-1) and 6257.762 cm -1 (Laser-2), respectively. A portion of Laser-1’s output was used by a frequency modulation spectroscopy technique to lock its frequency precisely at a CO 2 absorption peak, while the rest of its output was coupled to an optical ring-down cavity, together with the Laser-2 output. The Laser-2 operated at a non-absorbing frequency for real-time correction of any baseline ring-down time drift caused by environmental changes (e.g., temperature, pressure). Laser frequency stabilization achieved a 5-fold improvement in CRDS detection sensitivity. This new system was able to make measurements at a data rate of 9 Hz. Based on Allan deviation analysis, the absorbance detection limit of the system was 4.4 × 10 −11 cm -1 at an optimum averaging time of ∼5 s, whereas the time-normalized sensitivity at 1 s was 7.3 × 10 −11 cm -1 /Hz 1/2 . Measurements of atmospheric CO 2 mole fraction were conducted and demonstrated its good performance and reliability. This sensor will be particularly suitable for making drift-free measurements over long periods, in the fields of environmental and industrial gas sensing.

Förderung

  • National Natural Science Foundation of China
  • Youth Innovation Promotion Association of the Chinese Academy of Sciences

Zitieren

APA

Liu, Y., He, Y., Hu, M., Chen, B., Xu, Z., Yao, L., Wang, X., & Kan, R. (2023). Cavity ring-down spectroscopy with a laser frequency stabilized and locked to a reference target gas absorption for drift-free accurate gas sensing measurements. Frontiers in Physics, 11. https://doi.org/10.3389/fphy.2023.1238869

Vancouver

Liu Y, He Y, Hu M, Chen B, Xu Z, Yao L, et al. Cavity ring-down spectroscopy with a laser frequency stabilized and locked to a reference target gas absorption for drift-free accurate gas sensing measurements. Frontiers in Physics. 2023;11. doi:10.3389/fphy.2023.1238869

BibTeX
@article{Liu2023,
  author = {Liu, Ying and He, Yabai and Hu, Mai and Chen, Bing and Xu, Zhenyu and Yao, Lu and Wang, Xingping and Kan, Ruifeng},
  title = {Cavity ring-down spectroscopy with a laser frequency stabilized and locked to a reference target gas absorption for drift-free accurate gas sensing measurements},
  journal = {Frontiers in Physics},
  year = {2023},
  volume = {11},
  doi = {10.3389/fphy.2023.1238869}
}
Kostenlos starten →