EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Quality, readability, and information fidelity of large language model–generated versus physician-authored informed-consent content for targeted therapies: a blinded, paired comparative study

Qualität, Lesbarkeit und Informationsgenauigkeit von durch Large Language Models generierten versus von Ärzt:innen verfassten Einwilligungsinhalten zu zielgerichteten Therapien: verblindete gepaarte Vergleichsstudie

Yue Xie, Yuan Gao, Jiajing Peng, Yiling Tao, Shanshan Xu, Zhongwen Cui, Boya Zhou, Ente Wang, Li Cui

Frontiers in Pharmacology · 04.11.2026 · 17

DOI: 10.3389/fphar.2026.1958826 ↗

Auf einen Blick

Bei 70 erwachsenen Patient:innen waren LLM-Texte im Gesamtscore besser bewertet als ärztliche Texte. Gleichzeitig war das Leseniveau höher und es traten häufiger Halluzinationen auf.

Fragestellung

Unterscheiden sich von LLMs erzeugte Einwilligungstexte für zielgerichtete Therapien von ärztlich verfassten Texten in Qualität, Lesbarkeit und Informationsgenauigkeit?

Methode

Einzentrische, retrospektive, gepaarte, verblindete Multi-Evaluator-Studie. 70 Erwachsene in der Rheumatologie; LLM-Texte auf Basis anonymisierter Falldaten, ärztliche Texte aus Akten. Bewertung durch 3 Rheumatolog:innen.

Ergebnisse

140 Texte analysiert. LLMs: höherer Median im Gesamtscore (60 vs. 50; adjustierte mittlere Differenz 9,95; 95 %-KI 9,36–10,54; p < 0,01), höhere Werte für Risiken, Nutzen und Alternativen; höheres Leseniveau (7,87 vs. 7,10; p < 0,01) und mehr Halluzinationen (27,1 % vs. 0; p < 0,01).

Einschränkungen

Ein exploratives Single-Center-Design mit lokal entwickeltem Bewertungsrahmen; weitere Validierung mit patientenzentrierten Endpunkten erforderlich.

Schlussfolgerung der Autor:innen

LLM-Texte erhielten höhere Bewertungen und deckten vorgegebene Inhalte konsistenter ab. Sie enthielten jedoch häufiger unbelegte patientenspezifische Inferenzen und waren schwerer lesbar; für Endversionen ist ärztliche Prüfung nötig.

Kernaussagen

  • Gesamtscore höher bei LLM-Texten als bei ärztlichen Texten
  • Leseniveau höher und Halluzinationen häufiger bei LLM-Texten
  • Einsatz nur als Entwurf mit ärztlicher Prüfung und Einzelprüfung der Inhalte

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Pharmacology, online erschienen am 04.11.2026. Verfasst von Yue Xie und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacy, Beijing Tongren Hospital, Capital Medical University, Beijing, China. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare the content quality of basic information, risks, benefits, and alternative options in informed consent forms for targeted therapy generated by large language models (LLMs) versus those drafted by physicians, and to evaluate informational fidelity and reading level.

Methods

This study used a single-center, retrospective, paired-case, blinded multi-evaluator design. We enrolled 70 adult patients who received targeted therapy in the Department of Rheumatology at Beijing Tongren Hospital during 2025. LLM texts were generated using DeepSeek-V4-pro based on identical de-identified case data and standardized prompts, and corresponding physician texts were extracted from electronic records. Three rheumatologists performed blinded scoring using a scale comprising 8 domains and 13 items. Reading level and informational errors were assessed using CRIE 3.0 and source tracing.

Results

A total of 140 texts were analyzed. The LLM arm achieved a higher median overall quality score than the physician arm (60 vs. 50; adjusted mean difference 9.95, 95% CI 9.36 to 10.54; p < 0.01), with higher scores for risks, benefits, and alternatives (all adjusted p < 0.01). The LLM arm also exhibited higher reading level scores (7.87 vs. 7.10; p < 0.01) and a higher rate of hallucinations (27.1% vs. 0; p < 0.01). No statistically significant between-arm differences were found for inaccuracies or omissions.

Conclusion

In this exploratory study, according to a locally developed assessment framework, LLM-generated texts received higher composite evaluator ratings and more consistently covered predefined informed consent content domains. However, they more frequently contained unsupported patient-specific inferences and imposed a greater reading burden. LLMs may be useful for generating structured drafts and checking coverage of predefined content, but they should not be used to produce final informed consent documents without physician review and item-by-item verification. These findings require further validation using patient-centered outcomes.

Schlagwörter

Stichwörter der Autor:innen

clinical documentationinformed consentlarge language modelsrheumatologytargeted therapy

Autor:innen und Institutionen

  • Department of Pharmacy, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
  • Department of Rheumatology and Immunology, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
  • Department of Medical Affairs, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
  • Rehabilitation Hospital Affiliated to National Research Center for Rehabilitation Technical Aids, Beijing, China.
  • Department of Pharmacy, Beijing Obstetrics and Gynecology Hospital, Capital Medical University, Beijing Maternal and Child Health Care Hospital, Beijing, China.

Zitieren

APA

Xie, Y., Gao, Y., Peng, J., Tao, Y., Xu, S., Cui, Z., Zhou, B., Wang, E., & Cui, L. (2026). Quality, readability, and information fidelity of large language model–generated versus physician-authored informed-consent content for targeted therapies: a blinded, paired comparative study. Frontiers in Pharmacology, 17. https://doi.org/10.3389/fphar.2026.1958826

Vancouver

Xie Y, Gao Y, Peng J, Tao Y, Xu S, Cui Z, et al. Quality, readability, and information fidelity of large language model–generated versus physician-authored informed-consent content for targeted therapies: a blinded, paired comparative study. Frontiers in Pharmacology. 2026;17. doi:10.3389/fphar.2026.1958826

BibTeX
@article{Xie2026,
  author = {Xie, Yue and Gao, Yuan and Peng, Jiajing and Tao, Yiling and Xu, Shanshan and Cui, Zhongwen and Zhou, Boya and Wang, Ente and Cui, Li},
  title = {Quality, readability, and information fidelity of large language model–generated versus physician-authored informed-consent content for targeted therapies: a blinded, paired comparative study},
  journal = {Frontiers in Pharmacology},
  year = {2026},
  volume = {17},
  doi = {10.3389/fphar.2026.1958826}
}
Kostenlos starten →