EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Systemic absorption and nephrotoxicity of antibiotic-loaded cement spacers: pharmacokinetic principles and clinical risk management

Jixin Chen, Qinxin Zhou, Weijie Yu, Dongdong Cao, Yongming Zhang, Jianliang Chen, Xiaodong Zheng, Feng Ye

Frontiers in Pharmacology · 05.11.2026 · 17

DOI: 10.3389/fphar.2026.1958607 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Pharmacology, online erschienen am 05.11.2026. Verfasst von Jixin Chen und 7 weiteren Autor:innen. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Antibiotic-loaded polymethylmethacrylate (PMMA) spacers are widely used during staged revision for periprosthetic joint infection (PJI) to provide high local antimicrobial exposure, but they are not pharmacologically isolated from the systemic circulation. Human pharmacokinetic studies demonstrate measurable vancomycin and aminoglycoside concentrations after implantation, sometimes persisting for weeks, while clinical studies report heterogeneous rates of acute kidney injury (AKI) across populations and spacer regimens. Risk cannot be inferred from grams of antibiotic per 40 g of cement alone: formulation concentration, total implanted drug mass, cement mass, release kinetics, spacer geometry, concurrent systemic therapy, perioperative hemodynamics, and patient-specific renal clearance are related but distinct determinants of systemic exposure. This Mini Review integrates PMMA elution principles with quantitative human evidence, separates evidence of spacer-derived absorption from associations with AKI and from general perioperative risk factors, and proposes a pragmatic risk-management framework. The framework is not prospectively validated. Safer use requires stable-baseline renal risk assessment, explicit documentation of total antibiotic and cement doses, coordinated local and systemic prescribing, early monitoring in high-risk inpatients, selective serum drug measurement when exposure or toxicity is suspected, and multidisciplinary escalation for persistent toxicity. Future studies should use standardized dose, sampling, exposure, and KDIGO-defined renal outcome metrics and should distinguish spacer-derived from intravenously administered drug exposure.

Zitieren

APA

Chen, J., Zhou, Q., Yu, W., Cao, D., Zhang, Y., Chen, J., Zheng, X., & Ye, F. (2026). Systemic absorption and nephrotoxicity of antibiotic-loaded cement spacers: pharmacokinetic principles and clinical risk management. Frontiers in Pharmacology, 17. https://doi.org/10.3389/fphar.2026.1958607

Vancouver

Chen J, Zhou Q, Yu W, Cao D, Zhang Y, Chen J, et al. Systemic absorption and nephrotoxicity of antibiotic-loaded cement spacers: pharmacokinetic principles and clinical risk management. Frontiers in Pharmacology. 2026;17. doi:10.3389/fphar.2026.1958607

BibTeX
@article{Chen2026,
  author = {Chen, Jixin and Zhou, Qinxin and Yu, Weijie and Cao, Dongdong and Zhang, Yongming and Chen, Jianliang and Zheng, Xiaodong and Ye, Feng},
  title = {Systemic absorption and nephrotoxicity of antibiotic-loaded cement spacers: pharmacokinetic principles and clinical risk management},
  journal = {Frontiers in Pharmacology},
  year = {2026},
  volume = {17},
  doi = {10.3389/fphar.2026.1958607}
}
Kostenlos starten →