Automated EEG seizure detection in neonates with hypoxic–ischemic encephalopathy using temporal and morphological modeling
Frontiers in Pediatrics · 24.11.2026 · 14
DOI: 10.3389/fped.2026.2008200 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Pediatrics, online erschienen am 24.11.2026. Verfasst von Tianfang Dong und 5 weiteren Autor:innen. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Seizures are common in neonates with hypoxic–ischemic encephalopathy (HIE) and may be difficult to recognize clinically. Automated electroencephalography (EEG) analysis is therefore important for neonatal neurological monitoring. However, variable EEG backgrounds, brief abnormal discharges, and marked inter-patient differences remain major challenges.
Methods
We developed a temporal EEG framework for neonatal seizure detection. Multi-scale temporal convolution was used to capture local waveform changes, while a hierarchical state-space encoder modeled longer temporal dependencies. Micro-temporal morphological evolution gating, temporal-state attention pooling, and nuisance-state suppression were further introduced to enhance seizure-related information. The model was evaluated on the Helsinki dataset of 79 neonates and an independent clinical HIE cohort of 34 neonates. EEG signals were converted to an 18-channel longitudinal bipolar montage and segmented into 10 s windows with a 5 s stride. Patient-level stratified five-fold cross-validation was performed under the SPEED evaluation framework.
Results
On the Helsinki dataset, the model achieved an AUC of 94.78 % ± 2.75 % , AP of 82.58 % ± 11.46 % , F1 score of 75.69 % ± 11.81 % , and MCC of 73.48 % ± 11.37 % . Sensitivity and Specificity were 70.42 % ± 13.59 % and 98.16 % ± 1.15 % , respectively. On the clinical cohort, the corresponding values were 95.51 % ± 2.36 % , 84.24 % ± 10.31 % , 77.31 % ± 10.48 % , and 75.29 % ± 10.08 % , with Sensitivity of 71.28 % ± 12.14 % and Specificity of 98.54 % ± 0.63 % . Ablation and patient-level analyses supported the complementary contributions of morphology modeling, temporal-state selection, and interference suppression.
Conclusion
The proposed framework achieved consistent seizure detection performance in both public and clinical neonatal HIE EEG datasets. It may provide useful technical support for automated seizure screening and bedside neurological monitoring in neonates with HIE.
Zitieren
APA
Dong, T., Zhan, S., Shen, Y., Tao, W., Li, F., & Yu, J. (2026). Automated EEG seizure detection in neonates with hypoxic–ischemic encephalopathy using temporal and morphological modeling. Frontiers in Pediatrics, 14. https://doi.org/10.3389/fped.2026.2008200
Vancouver
Dong T, Zhan S, Shen Y, Tao W, Li F, Yu J. Automated EEG seizure detection in neonates with hypoxic–ischemic encephalopathy using temporal and morphological modeling. Frontiers in Pediatrics. 2026;14. doi:10.3389/fped.2026.2008200
BibTeX
@article{Dong2026,
author = {Dong, Tianfang and Zhan, Shina and Shen, Yingjie and Tao, Wan and Li, Feitian and Yu, Jinqian},
title = {Automated EEG seizure detection in neonates with hypoxic–ischemic encephalopathy using temporal and morphological modeling},