Feasibility of Laryngeal Mask Airway insertion during continuous chest compressions in neonatal resuscitation: a randomized crossover simulation study

Machbarkeit der Larynxmasken-Atemwegseinlage während kontinuierlicher Thoraxkompressionen in der neonatalen Reanimation: randomisierte Crossover-Simulationsstudie

Cengizhan Yavuz, Emel Gündüz, Gözen Öksüz

Frontiers in Pediatrics · 11.11.2026 · 14

DOI: 10.3389/fped.2026.2006542 ↗

Auf einen Blick

In einer Simulationsstudie mit 32 Ärzt:innen war die Larynxmasken-Einlage unter kontinuierlichen Thoraxkompressionen machbar. Einlegungszeit, Erstversagerate und subjektive Schwierigkeit unterschieden sich nicht wesentlich.

Fragestellung

Sind Einlage und Ventilation mit der Larynxmaske während kontinuierlicher Thoraxkompressionen in der neonatalen Reanimation machbar?

Methode

Randomisierte Crossover-Simulationsstudie an einem hochrealistischen neonatalen Manikin; beide Szenarien in zufälliger Reihenfolge.

Ergebnisse

32 Ärzt:innen. Einlegungszeit: 10,47 ± 2,00 s vs. 10,28 ± 1,82 s; p > 0,05. Erstversuchserfolg: 100 % vs. 96,9 %. Air leak: 0,186 ± 0,040 vs. 0,164 ± 0,029 L/min; p < 0,001.

Einschränkungen

Simulationsmodell; Autoren betonen Proof-of-concept statt formaler statistischer Äquivalenz. Die Ursache des geringeren Air leaks bleibt unklar.

Schlussfolgerung der Autor:innen

Die Larynxmasken-Einlage während kontinuierlicher Thoraxkompressionen war in diesem Simulationsmodell machbar und mit hoher Erstversuchsrate möglich.

Kernaussagen

  • 32 Ärzt:innen nahmen teil
  • Einlegungszeit und Schwierigkeit unterschieden sich nicht wesentlich
  • Unter kontinuierlichen Kompressionen war der Air leak geringer

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Pediatrics, online erschienen am 11.11.2026. Verfasst von Cengizhan Yavuz und 2 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

Auf einen BlickAbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The objective is to assess the times taken for laryngeal mask airway (LMA®) placement, successful LMA placement, successful ventilation, and minute air leak amounts during interrupted (Scenario A) and continuous (Scenario B) chest compressions during simulated neonatal resuscitation. Material and methods In this randomized crossover simulation study, participating physicians performed both scenarios in a randomly allocated sequence on a high-fidelity neonatal manikin. The evaluated parameters were LMA placement times, first-attempt placement success, minute ventilation (MV), air leak volume, device-related complications, and procedural difficulty scores (VAS).

Results

A total of 32 physicians (16 attending anesthesiologists and 16 senior residents) completed the study. No statistical difference was observed between Scenario A and Scenario B regarding LMA insertion times (10.47 ± 2.00 s vs. 10.28 ± 1.82 s; p > 0.05) and first-attempt success rates (100% vs. 96.9%). Minute ventilation remained at the 0.50 L/min target in 27 of 32 participants under Scenario B (median 0.50 L/min in both scenarios). Air leak was lower in Scenario B (0.186 ± 0.040 vs. 0.164 ± 0.029 L/min; p < 0.001). Median VAS difficulty scores did not differ significantly between scenarios (1.0 vs. 1.0; p = 0.159), and no complications were observed. Although a 1.0 s learning effect was detected in the analyses, this momentum was distributed symmetrically to the data due to the crossover design.

Conclusion

In this simulated neonatal resuscitation model, LMA insertion during continuous chest compressions was feasible and maintained high first-attempt success. These findings should be interpreted as a proof-of-concept rather than formal statistical equivalence. The cause of the observed reduction in air leak under continuous compressions remains uncertain and may partly reflect instrument resolution limits rather than a true physiological effect. Furthermore, perceived procedural difficulty did not differ significantly between scenarios, and no device-related complications such as LMA folding or asymmetric chest rise were observed. Clinical Trial Registration : https://clinicaltrial.gov/ , identifier NCT07681960.

Zitieren

APA

Yavuz, C., Gündüz, E., & Öksüz, G. (2026). Feasibility of Laryngeal Mask Airway insertion during continuous chest compressions in neonatal resuscitation: a randomized crossover simulation study. Frontiers in Pediatrics, 14. https://doi.org/10.3389/fped.2026.2006542

Vancouver

Yavuz C, Gündüz E, Öksüz G. Feasibility of Laryngeal Mask Airway insertion during continuous chest compressions in neonatal resuscitation: a randomized crossover simulation study. Frontiers in Pediatrics. 2026;14. doi:10.3389/fped.2026.2006542