Comparison of detection frequencies between ultrasonography and abdominal radiography for abnormal signs in necrotizing enterocolitis: a systematic review and meta-analysis
Frontiers in Pediatrics · 29.07.2026 · 14
DOI: 10.3389/fped.2026.1889902 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Frontiers in Pediatrics, online erschienen am 29.07.2026. Verfasst von Jinglan Huang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, China. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Sichuan Province.
Abstract (Originalsprache)
Objective
To synthesize the existing evidence regarding the differences between abdominal ultrasound (AUS) and conventional radiography in detecting necrotizing enterocolitis (NEC) features in neonates.
Methods
A six-database literature search was conducted to identify relevant English-language studies published prior to April 1, 2026 comparing the detection frequencies of AUS and abdominal x-ray (AXR) for imaging signs of neonatal NEC.
Results
Twenty studies were identified that systematically compared the detection frequencies of AUS vs. AXR for detecting specific NEC features ( n = 1,793 neonates with confirmed or suspected NEC). AUS detected portal venous gas more frequently than AXR [odds ratio (OR): 2.32; 95% confidence interval (CI) [1.35–3.99]] and exhibits a higher, albeit not significant, detection frequency for pneumatosis intestinalis [OR: 1.21; 95% CI (0.82–1.80)]. AXR detected pneumoperitoneum [OR: 0.62; 95% CI (0.31–1.26)] and intestinal dilatation [OR: 0.51; 95% CI (0.19–1.40)] more frequently than AUS, though neither frequency was statistically significant.
Conclusions
AUS and AXR show different patterns of detection of abnormal signs in NEC, with the former detecting portal gas and pneumatosis intestinalis more frequently than the latter. Combining the two modalities in clinical practice may facilitate earlier recognition and assessment of disease progression in neonatal NEC cases.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, China.
- Key Laboratory of Birth Defects and Related Diseases of Women and Children of the Ministry of Education, Sichuan University, Chengdu, Sichuan, China.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Sichuan Province
Zitieren
APA
Huang, J., Gao, Q., Xu, Z., & Li, X. (2026). Comparison of detection frequencies between ultrasonography and abdominal radiography for abnormal signs in necrotizing enterocolitis: a systematic review and meta-analysis. Frontiers in Pediatrics, 14. https://doi.org/10.3389/fped.2026.1889902
Vancouver
Huang J, Gao Q, Xu Z, Li X. Comparison of detection frequencies between ultrasonography and abdominal radiography for abnormal signs in necrotizing enterocolitis: a systematic review and meta-analysis. Frontiers in Pediatrics. 2026;14. doi:10.3389/fped.2026.1889902
BibTeX
@article{Huang2026,
author = {Huang, Jinglan and Gao, Qian and Xu, Ziqing and Li, Xin},
title = {Comparison of detection frequencies between ultrasonography and abdominal radiography for abnormal signs in necrotizing enterocolitis: a systematic review and meta-analysis},
journal = {Frontiers in Pediatrics},
year = {2026},
volume = {14},
doi = {10.3389/fped.2026.1889902}
}
EUVIMED