uFlowAM: an unsupervised framework for detection and visualization of abnormal intracardiac microflow on early-pregnancy fetal cardiac microflow imaging

Yan Xia, Yarui Wei, Zhanru Lan, Ning Wu, Yongxin Li, Xueqin Ji

Frontiers in Pediatrics · 09.07.2026 · 14

DOI: 10.3389/fped.2026.1888687 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Pediatrics, online erschienen am 09.07.2026. Verfasst von Yan Xia und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound Medicine, Peking University First Hospital Ningxia Women and Children's Hospital (Ningxia Hui Autonomous Region Maternal and…. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Congenital heart disease (CHD) is a clinically important fetal anomaly. Early-pregnancy fetal cardiac microflow imaging (FCMI) can show low-velocity intracardiac flow, but brief shunt-related, regurgitant, and outflow-tract disturbances remain difficult to recognize when image quality, fetal position, and gestational age vary across examinations.

Objective

To evaluate uFlowAM for fetus-level detection and visualization of abnormal intracardiac microflow patterns on early-pregnancy FCMI.

Methods

This multicenter diagnostic accuracy study analyzed 650 early-pregnancy FCMI examinations from fetuses referred for suspected CHD or CHD risk assessment, including 500 examinations in the internal cohort and 150 in the external cohort. Standard four-chamber, left ventricular outflow tract (LVOT), and right ventricular outflow tract (RVOT) clips were processed by microflow extraction, cardiac-cycle alignment, signal normalization, and 16-frame windowing. uFlowAM used self-supervised training to learn a 256-dimensional representation of control fetal microflow from temporal-order discrimination and masked-frame reconstruction. Model training used no pixel-level or lesion-level labels. Control embeddings were grouped by view and cardiac phase to build a normal microflow template library, and an abnormality index (AbI) was calculated from latent-space Mahalanobis distances. The operating threshold was calibrated in internal validation and then kept fixed for external testing. Clinical utility was assessed in a 9-reader, 240-case multi-reader multi-case (MRMC) study.

Results

Using the fixed operating threshold ( τ * = 2.15), uFlowAM achieved an area under the receiver operating characteristic curve (AUC) of 0.94 (95% CI, 0.92–0.96), sensitivity of 0.92, and specificity of 0.88 in the internal cohort. In the external cohort, AUC was 0.92 (95% CI, 0.88–0.95), with sensitivity of 0.90 and specificity of 0.86. Median reader-level AUC increased from 0.85 to 0.92 with uFlowAM assistance, weighted kappa for subtype agreement increased from 0.62 to 0.78, visibility scores increased from 2.8 ± 0.6 to 4.3 ± 0.5, and median reading time decreased from 78 s to 59 s. Mean inference time was 6.8 ± 1.3 s per case.

Conclusions

In this CHD-enriched referral/risk-assessment cohort, uFlowAM detected abnormal early-pregnancy fetal cardiac microflow patterns and improved reader consistency and efficiency on selected fetal cardiac microflow views. The framework should be considered an assistive second-reader tool for early fetal CHD assessment. It should not be used as a substitute for a complete fetal echocardiographic examination.

Schlagwörter

Stichwörter der Autor:innen

SlowFlowHDanomaly detectioncongenital heart diseaseearly pregnancyfetal cardiac microflow imagingfetal cardiologyunsupervised learningvisualization

Autor:innen und Institutionen

  • Department of Ultrasound Medicine, Peking University First Hospital Ningxia Women and Children's Hospital (Ningxia Hui Autonomous Region Maternal and Child Health Hospital), Yinchuan, Ningxia Hui Autonomous Region, Chin…
  • The Third Clinical College, Ningxia Medical University, Yinchuan, Ningxia, China.
  • Department of Ultrasonography, Ningxia Guyuan Maternal and Child Health Hospital, Guyuan, Ningxia Hui Autonomous Region, China.
  • Department of Thoracic Surgery, Beijing Genertec Aerospace Hospital, Beijing, China.
  • School of Automation and Intelligence, Beijing Jiaotong University, Beijing, China.

Zitieren

APA

Xia, Y., Wei, Y., Lan, Z., Wu, N., Li, Y., & Ji, X. (2026). uFlowAM: an unsupervised framework for detection and visualization of abnormal intracardiac microflow on early-pregnancy fetal cardiac microflow imaging. Frontiers in Pediatrics, 14. https://doi.org/10.3389/fped.2026.1888687

Vancouver

Xia Y, Wei Y, Lan Z, Wu N, Li Y, Ji X. uFlowAM: an unsupervised framework for detection and visualization of abnormal intracardiac microflow on early-pregnancy fetal cardiac microflow imaging. Frontiers in Pediatrics. 2026;14. doi:10.3389/fped.2026.1888687

BibTeX
@article{Xia2026,
  author = {Xia, Yan and Wei, Yarui and Lan, Zhanru and Wu, Ning and Li, Yongxin and Ji, Xueqin},
  title = {uFlowAM: an unsupervised framework for detection and visualization of abnormal intracardiac microflow on early-pregnancy fetal cardiac microflow imaging},
  journal = {Frontiers in Pediatrics},
  year = {2026},
  volume = {14},
  doi = {10.3389/fped.2026.1888687}
}
Kostenlos starten →