EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyseOpen Access · CC BY 4.0

Diagnostic accuracy of lung ultrasound for transient tachypnea of the newborn: a meta-analysis

Yan Niu, Dong Han, Chen Kou

Frontiers in Pediatrics · 24.06.2026 · 14

DOI: 10.3389/fped.2026.1855601 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Frontiers in Pediatrics, online erschienen am 24.06.2026. Verfasst von Yan Niu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neonatology, Beijing Obstetrics and Gynecology Hospital, Capital Medical University, Beijing Maternal and Child Health Care Hospital, B…. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study aimed to evaluate the accuracy and reliability of lung ultrasound (LUS) for diagnosing transient tachypnea of the newborn (TTN) through a meta-analysis.

Methods

Relevant studies were retrieved from PubMed, Web of Science, the Cochrane Library, Ovid, Scopus, and Embase databases without restrictions on language or publication date, up to December 31, 2025. Studies evaluating the diagnostic performance of LUS for TTN were included. Two researchers independently extracted data and assessed study quality using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Statistical analyses were performed using Meta-DiSc 1.4, Stata 18.0 and RevMan 5.4 software.

Results

Ten studies comprising 1,747 newborns were included in the analysis. The overall methodological quality of the included studies was moderate to high. Threshold analysis indicated no threshold effect. The pooled sensitivity, specificity, positive likelihood ratio (PLR), and negative likelihood ratio (NLR) of LUS for diagnosing TTN were 0.93 (95% confidence interval [CI]: 0.78–0.98), 0.99 (95% CI: 0.97–1.00), 81.64 (95% CI: 26.19–254.45), and 0.07 (95% CI: 0.02–0.24), respectively. The pooled diagnostic odds ratio (DOR) was 1113.94 (95% CI: 143.77–8631.13), and the area under the curve (AUC) was 0.97. Meta-regression demonstrated that LUS exhibited significant diagnostic accuracy for TTN.

Conclusion

LUS is a promising modality for diagnosing TTN; however, its diagnostic accuracy varies considerably depending on study design and diagnostic criteria. Further studies are warranted to validate the utility of LUS in the diagnosis of TTN.

Schlagwörter

Stichwörter der Autor:innen

diagnosislung ultrasoundmeta-analysisnewborntransient tachypnea

Autor:innen und Institutionen

  • Department of Neonatology, Beijing Obstetrics and Gynecology Hospital, Capital Medical University, Beijing Maternal and Child Health Care Hospital, Beijing, China.

Zitieren

APA

Niu, Y., Han, D., & Kou, C. (2026). Diagnostic accuracy of lung ultrasound for transient tachypnea of the newborn: a meta-analysis. Frontiers in Pediatrics, 14. https://doi.org/10.3389/fped.2026.1855601

Vancouver

Niu Y, Han D, Kou C. Diagnostic accuracy of lung ultrasound for transient tachypnea of the newborn: a meta-analysis. Frontiers in Pediatrics. 2026;14. doi:10.3389/fped.2026.1855601

BibTeX
@article{Niu2026,
  author = {Niu, Yan and Han, Dong and Kou, Chen},
  title = {Diagnostic accuracy of lung ultrasound for transient tachypnea of the newborn: a meta-analysis},
  journal = {Frontiers in Pediatrics},
  year = {2026},
  volume = {14},
  doi = {10.3389/fped.2026.1855601}
}