Factors influencing diagnostic discrepancy between preoperative transthoracic echocardiography and cardiovascular angiography in patent ductus arteriosus intervention: a multicenter retrospective study
Frontiers in Pediatrics · 11.03.2026 · 14
DOI: 10.3389/fped.2026.1733629 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Pediatrics, online erschienen am 11.03.2026. Verfasst von Huimin Ou und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Cardiology, Ultrasound, Sichuan Provincial Women's and Children's Hospital/The Affiliated Women's and Children' Hospital of C…. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Discrepancies between transthoracic echocardiography (TTE) and angiocardiography in assessing patent ductus arteriosus (PDA) dimensions may impact transcatheter closure outcomes.
Methods
This multicenter retrospective study included 216 pediatric patients who underwent PDA closure, aiming to evaluate the prevalence and predictors of TTE-angiocardiography measurement discrepancy (defined as ≥0.5 mm difference).
Results
45.4% of patients exhibited significant discrepancy. Multivariate analysis identified tubular PDA morphology (OR = 2.71, P = 0.004), small PDA size (<2.5 mm, OR = 3.42, p < 0.001), preterm birth (OR = 2.87, p = 0.003), growth retardation (OR = 2.19, p = 0.022), and abnormal ECG, chest x-ray, or cardiac enzymes (ORs: 1.96–2.05, all p < 0.05) as independent predictors. Measurement agreement was highest for funnel-type and larger PDAs. Dsicussion Nearly half of pediatric PDA cases show clinically relevant TTE-angiography discordance, particularly in patients with tubular morphology, small size, prematurity, or systemic abnormalities. These factors should prompt cautious interpretation of TTE and consideration of intraoperative angiographic confirmation to optimize device selection and procedural success.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatric Cardiology, Ultrasound, Sichuan Provincial Women's and Children's Hospital/The Affiliated Women's and Children' Hospital of Chengdu Medical College, Chengdu, Sichuan, China.
- Department of Pediatrics, West China Hospital Sichuan University Jintang Hospital, Jintang First People's Hospital, Chengdu, Sichuan, China.
- Department of Pediatric Cardiology, Chengdu Women's and Children's Central Hospital, Chengdu, Sichuan, China.
Zitieren
APA
Ou, H., Wang, Q., Zhang, X., Li, F., Yang, Y., Ji, X., Bai, Y., Luo, T., & Wang, X. (2026). Factors influencing diagnostic discrepancy between preoperative transthoracic echocardiography and cardiovascular angiography in patent ductus arteriosus intervention: a multicenter retrospective study. Frontiers in Pediatrics, 14. https://doi.org/10.3389/fped.2026.1733629
Vancouver
Ou H, Wang Q, Zhang X, Li F, Yang Y, Ji X, et al. Factors influencing diagnostic discrepancy between preoperative transthoracic echocardiography and cardiovascular angiography in patent ductus arteriosus intervention: a multicenter retrospective study. Frontiers in Pediatrics. 2026;14. doi:10.3389/fped.2026.1733629
BibTeX
@article{Ou2026,
author = {Ou, Huimin and Wang, Qingsong and Zhang, Xiaomeng and Li, Fuyan and Yang, Yanfeng and Ji, Xuehong and Bai, Yan and Luo, Tongyong and Wang, Xianmin},
title = {Factors influencing diagnostic discrepancy between preoperative transthoracic echocardiography and cardiovascular angiography in patent ductus arteriosus intervention: a multicenter retrospective study},
journal = {Frontiers in Pediatrics},
year = {2026},
volume = {14},
doi = {10.3389/fped.2026.1733629}
}
EUVIMED