EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY 4.0

Effectiveness of mechanical vibration-assisted sputum clearance in pediatric pneumonia: a randomized controlled trial with development of an intelligent parameter optimization model

Sujing Xue, Kewu Lin, Ledan Lin, Huijie Zhou, Lishuang Dong, Huafen Chen, Tengfei Zhang

Frontiers in Pediatrics · 26.06.2025 · 13

DOI: 10.3389/fped.2025.1539218 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Frontiers in Pediatrics, online erschienen am 26.06.2025. Verfasst von Sujing Xue und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Internal Medicine, Wenzhou People's Hospital, Wenzhou Maternal and Child Health Care Hospital, Wenzhou, Zhejiang, China. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Sputum retention in pediatric pneumonia hinders recovery. This study evaluated the therapeutic benefits of incorporating mechanical vibration-assisted sputum clearance (MVSC) as an adjunct to standard pharmacological treatment and developed a nomogram to optimize treatment parameters.

Methods

In this randomized controlled trial, 160 children with pneumonia were randomly assigned (1:1) to a control group receiving pharmacological treatment or a treatment group receiving additional mechanical vibration therapy. The proportion of patients showing clinical improvement (defined as “markedly improved” or “improved”) was assessed, along with symptom resolution times, lung function, blood gas parameters, and inflammatory markers, which were measured at baseline and treatment completion. LASSO regression identified predictors of clinical improvement.

Results

A significantly greater proportion of patients exhibited clinical improvement in the treatment group (93.75%) compared to the control group (75%, P < 0.05). The treatment group also showed significantly shorter times for symptom resolution (pulmonary rales, fever, and cough) and hospital stay ( P < 0.05). Improvements in lung function (FEV1, FEV1/FVC), blood gas parameters (PaO₂, PaCO₂, pH), and greater reductions in inflammatory markers (CRP, PCT), were observed in the treatment group ( P < 0.05). A nomogram was developed using age, chest circumference, moist rales, disease severity, vibration frequency, and pressure to determine optimal mechanical vibration settings for individualized treatment. The nomogram showed high predictive accuracy (AUC = 0.943) in estimating clinical improvement, aiding in the optimization of MVSC in pediatric pneumonia.

Conclusions

MVSC enhances the treatment of pediatric pneumonia, with the nomogram optimizing the parameters of the sputum clearance device.

Schlagwörter

Stichwörter der Autor:innen

mechanical vibrationnomogramoptimizing parameterspediatric pneumoniasputum clearance

Autor:innen und Institutionen

  • Department of Pediatric Internal Medicine, Wenzhou People's Hospital, Wenzhou Maternal and Child Health Care Hospital, Wenzhou, Zhejiang, China.
  • Department of Nursing, Wenzhou People's Hospital, Wenzhou Maternal and Child Health Care Hospital, Wenzhou, Zhejiang, China.

Zitieren

APA

Xue, S., Lin, K., Lin, L., Zhou, H., Dong, L., Chen, H., & Zhang, T. (2025). Effectiveness of mechanical vibration-assisted sputum clearance in pediatric pneumonia: a randomized controlled trial with development of an intelligent parameter optimization model. Frontiers in Pediatrics, 13. https://doi.org/10.3389/fped.2025.1539218

Vancouver

Xue S, Lin K, Lin L, Zhou H, Dong L, Chen H, et al. Effectiveness of mechanical vibration-assisted sputum clearance in pediatric pneumonia: a randomized controlled trial with development of an intelligent parameter optimization model. Frontiers in Pediatrics. 2025;13. doi:10.3389/fped.2025.1539218

BibTeX
@article{Xue2025,
  author = {Xue, Sujing and Lin, Kewu and Lin, Ledan and Zhou, Huijie and Dong, Lishuang and Chen, Huafen and Zhang, Tengfei},
  title = {Effectiveness of mechanical vibration-assisted sputum clearance in pediatric pneumonia: a randomized controlled trial with development of an intelligent parameter optimization model},
  journal = {Frontiers in Pediatrics},
  year = {2025},
  volume = {13},
  doi = {10.3389/fped.2025.1539218}
}
Kostenlos starten →