EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Mechanical power and normalized mechanical power in pediatric acute respiratory distress syndrome

Farhan A R Shaikh, Karthik N Ramaswamy, Dinesh K Chirla, Shekhar T Venkataraman, Martin C J Kneyber

Frontiers in Pediatrics · 16.01.2024 · 12

DOI: 10.3389/fped.2024.1293639 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Pediatrics, online erschienen am 16.01.2024. Verfasst von Farhan A R Shaikh und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Intensive Care, Rainbow Children's Hospital, Hyderabad, India. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Mechanical power (MP) refers to the energy transmitted over time to the respiratory system and serves as a unifying determinant of ventilator-induced lung injury. MP normalization is required to account for developmental changes in children. We sought to examine the relationship between mechanical energy (ME BW ), MP normalized to body weight (MP BW ), and MP normalized to respiratory compliance (MP CRS ) concerning the severity and outcomes of pediatric acute respiratory distress syndrome (pARDS).

Method

In this retrospective study, children aged 1 month to 18 years diagnosed with pARDS who underwent pressure-control ventilation for at least 24 h between January 2017 and September 2020 were enrolled. We calculated MP using Becher's equation. Multivariable logistic regression analysis adjusted for age, pediatric organ dysfunction score, and oxygenation index (OI) was performed to determine the independent association of MP and its derivatives 24 h after diagnosing pARDS with 28-day mortality. The association was also studied for 28 ventilator-free days (VFD-28) and the severity of pARDS in terms of OI.

Results

Out of 246 admitted with pARDS, 185 were eligible, with an overall mortality of 43.7%. Non-survivors exhibited higher severity of illness, as evidenced by higher values of MP, MP BW , and ME BW . Multivariable logistic regression analysis showed that only ME BW but not MP, MP BW , or MP CRS at 24 h was independently associated with mortality [adjusted OR: 1.072 (1.002–1.147), p = 0.044]. However, after adjusting for the type of pARDS, ME BW was not independently associated with mortality [adjusted OR: 1.061 (0.992–1.136), p = 0.085]. After adjusting for malnutrition, only MP at 24 h was found to be independently associated. Only MP CRS at 1–4 and 24 h but not MP, MP BW , or ME BW at 24 h of diagnosing pARDS was significantly correlated with VFD-28.

Conclusions

Normalization of MP is better related to outcomes and severity of pARDS than non-normalized MP. Malnutrition can be a significant confounding factor in resource-limited settings.

Schlagwörter

Stichwörter der Autor:innen

mechanical energymechanical powermechanical ventilationnormalized mechanical powerpediatric acute respiratory distress syndromeventilator-induced lung injury

Autor:innen und Institutionen

  • Department of Pediatric Intensive Care, Rainbow Children's Hospital, Hyderabad, India.
  • Department of Pediatric Intensive Care, Rainbow Children's Hospital, Chennai, India.
  • Departments of Critical Care Medicine and Pediatrics, University of Pittsburgh School of Medicine, Pittsburgh, PA, United States.
  • Division of Paediatric Critical Care Medicine, Department of Paediatrics, Beatrix Children's Hospital, University Medical Center Groningen, University of Groningen, Groningen, Netherlands.
  • Critical Care, Anaesthesiology, Peri-Operative & Emergency Medicine (CAPE), University of Groningen, Groningen, Netherlands.

Zitieren

APA

Shaikh, F. A. R., Ramaswamy, K. N., Chirla, D. K., Venkataraman, S. T., & Kneyber, M. C. J. (2024). Mechanical power and normalized mechanical power in pediatric acute respiratory distress syndrome. Frontiers in Pediatrics, 12. https://doi.org/10.3389/fped.2024.1293639

Vancouver

Shaikh FAR, Ramaswamy KN, Chirla DK, Venkataraman ST, Kneyber MCJ. Mechanical power and normalized mechanical power in pediatric acute respiratory distress syndrome. Frontiers in Pediatrics. 2024;12. doi:10.3389/fped.2024.1293639

BibTeX
@article{Shaikh2024,
  author = {Shaikh, Farhan A R and Ramaswamy, Karthik N and Chirla, Dinesh K and Venkataraman, Shekhar T and Kneyber, Martin C J},
  title = {Mechanical power and normalized mechanical power in pediatric acute respiratory distress syndrome},
  journal = {Frontiers in Pediatrics},
  year = {2024},
  volume = {12},
  doi = {10.3389/fped.2024.1293639}
}
Kostenlos starten →