Background

This study systematically assesses the diagnostic accuracy of Node Reporting and Data System (Node-RADS) for lymph node (LN) metastasis in breast cancer (BC) and thyroid cancer (TC) via meta-analysis.

Methods

PubMed, Embase, Cochrane Library, and Web of Science were searched for clinical studies. BC and TC were jointly considered because they may be managed within the same breast–thyroid surgery specialty in certain healthcare systems; nevertheless, they were analyzed separately, and TC data were not pooled with the BC estimates. Literature screening, data extraction, and quality assessment were conducted. A bivariate random-effects model was applied. Stata 15.0 was used to pool sensitivity (SEN), specificity (SPE), and area under the receiver operating characteristic curve (AUC) values.

Results

For BC, as Node-RADS cutoff value increased from 1 to 3, pooled SEN decreased from 0.86 to 0.43, and SPE increased from 0.74 to 0.98. For cutoff=4, robust meta-analytic pooled estimates were lacking; therefore, only a qualitative description was provided. At cutoff=2, best balance was achieved with pooled SEN of 0.67 (95% confidence interval [CI]: 0.53–0.79), SPE of 0.93 (95% CI: 0.89–0.96), and AUC of 0.92 (95% CI: 0.89–0.94). Cutoff=1 yielded the highest SEN; however, its SPE was only 0.74, potentially resulting in numerous false positives. At cutoff=2, the AUC reached 0.92, and the subgroup analysis showed that the pooled SEN increased progressively with the interpreting physicians’ clinical experience, while SPE remained high and increased slightly, with a corresponding increase in AUC. Cutoffs of 3 showed extremely high SPE (≥0.97). Limited studies were included for TC; accordingly, the relevant findings were presented only as exploratory and descriptive.

Conclusion

Node-RADS is a reliable, standardized tool for assessing LN metastasis in BC, and cutoff=2 provides the most balanced performance in BC. However, given that the pooled SEN is only moderate (0.67), the negative results at cutoff=2 warrant further correlative assessment in combination with clinical and imaging findings. Given limitations in the available data, diagnostic performance in TC may not be pooled in a meta-analysis and remains to be validated. Large-sample prospective studies are needed to refine the assessment criteria and explore Node-RADS in other malignancies, including TC. Systematic review registration https://www.crd.york.ac.uk/PROSPERO/view/CRD420261278918 , identifier CRD420261278918.

Zitieren

APA

Zhang, X., Zhu, Y., Yan, X., & Ma, M. (2026). Diagnostic accuracy of node-RADS for lymph node metastasis in breast cancer and thyroid cancer: a systematic review and meta-analysis. Frontiers in Oncology, 16. https://doi.org/10.3389/fonc.2026.2004368

Vancouver

Zhang X, Zhu Y, Yan X, Ma M. Diagnostic accuracy of node-RADS for lymph node metastasis in breast cancer and thyroid cancer: a systematic review and meta-analysis. Frontiers in Oncology. 2026;16. doi:10.3389/fonc.2026.2004368

BibTeX
@article{Zhang2026,
  author = {Zhang, Xinran and Zhu, Yinbin and Yan, Xianxin and Ma, Min},
  title = {Diagnostic accuracy of node-RADS for lymph node metastasis in breast cancer and thyroid cancer: a systematic review and meta-analysis},
  journal = {Frontiers in Oncology},
  year = {2026},
  volume = {16},
  doi = {10.3389/fonc.2026.2004368}
}
Kostenlos starten →