EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accuracy and clinical utility of the compact micro-robot: a retrospective study of 95 cases

Wen Wang, Zairan Wang, Dabiao Zhou, Xiaohui Ren

Frontiers in Oncology · 03.08.2026 · 16

DOI: 10.3389/fonc.2026.1902506 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Oncology, online erschienen am 03.08.2026. Verfasst von Wen Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Robotic platforms for stereotactic neurosurgery have evolved rapidly, but compact systems have not been clinically validated in large cohorts.

Objective

To assess targeting accuracy and safety of the compact micro-robot (Q300, 1.5 kg, three-dimensional structured-light registration) across multiple stereotactic procedures, and to contextualize its performance against published data from established platforms.

Methods

We retrospectively analyzed 95 consecutive patients who underwent Q300-guided neurosurgery at Beijing Tiantan Hospital (October 2022–August 2024). Procedures included brain biopsy (n=57), ventriculoperitoneal shunt (n=17), CSF bypass procedures (n=17), and catheter drainage (n=4). The primary outcome was targeting error (TE), defined as the Euclidean distance between planned and actual target points on fused postoperative CT. Entry error (EE) was defined as the Euclidean distance between planned and actual entry points on the skull surface. Secondary outcomes included diagnostic yield, complication rate, and operative time.

Results

The mean EE was 0.92 ± 0.47 mm (median 0.85, IQR 0.55–1.20), and the mean TE was 0.95 ± 0.56 mm (median 0.88, IQR 0.56–1.22). All 57 biopsies yielded conclusive histopathological diagnosis (100% diagnostic tissue acquisition rate). The complication rate was 6.3% (6/95), including 3 hemorrhages managed conservatively and 3 infections after temporal horn bypass. No mortality or permanent neurological deficit occurred. The mean operative time was 73.8 ± 31.1 min (range 17–240) in 95 procedures.

Conclusion

The compact micro-robot achieved submillimetric median accuracy, 100% diagnostic tissue acquisition, and efficient operative times across 95 procedures. Its lightweight design and rapid registration offer practical workflow advantages. The infection rate in temporal horn bypass (3/10) requires further investigation.

Schlagwörter

Stichwörter der Autor:innen

Q300brain biopsycompactmicro-robottargeting error

Autor:innen und Institutionen

  • Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.

Zitieren

APA

Wang, W., Wang, Z., Zhou, D., & Ren, X. (2026). Accuracy and clinical utility of the compact micro-robot: a retrospective study of 95 cases. Frontiers in Oncology, 16. https://doi.org/10.3389/fonc.2026.1902506

Vancouver

Wang W, Wang Z, Zhou D, Ren X. Accuracy and clinical utility of the compact micro-robot: a retrospective study of 95 cases. Frontiers in Oncology. 2026;16. doi:10.3389/fonc.2026.1902506

BibTeX
@article{Wang2026,
  author = {Wang, Wen and Wang, Zairan and Zhou, Dabiao and Ren, Xiaohui},
  title = {Accuracy and clinical utility of the compact micro-robot: a retrospective study of 95 cases},
  journal = {Frontiers in Oncology},
  year = {2026},
  volume = {16},
  doi = {10.3389/fonc.2026.1902506}
}
Kostenlos starten →