The impact of positioning errors on the dose distribution of hypofractionated radiotherapy for left-sided radical breast cancer
Frontiers in Oncology · 24.04.2026 · 16
DOI: 10.3389/fonc.2026.1805689 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Oncology, online erschienen am 24.04.2026. Verfasst von Pan Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, General Hospital of Ningxia Medical University, Yinchuan, Ningxia, China. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To evaluate the impact of setup errors on the dosimetry of targets and organs at risk (OARs) in the mode of Hypofractionated radiotherapy(HFRT) for left-sided radical breast cancer, particularly on the esophagus, thyroid and left anterior descending artery (LAD).
Methods
30 patients were prescribed with 43.5Gy in 15 fractions. Positioning uncertainties were simulated by shifting the isocenter of 3, 5, 7, and 9 mm in six directions. Deviations in dosimetry were analyzed for the supraclavicular and the chest wall clinical target volume (CTV sc and CTV cw ), the heart, the LAD, the esophagus, and the thyroid under different setup errors.
Results
For D 95% (dose covering 95% of the target volume), the CTV sc and CTV cw were most sensitive to errors in the superior (S) and anterior (A) directions, respectively. As the positioning error increased from 3 to 9 mm, the decrease in D 95% for CTV sc in the S direction increased from 0.40 Gy to 4.49 Gy, while that for CTV cw in the A direction rose from 0.83 Gy to 11.26 Gy. Among OARs, the dose increase in the esophagus and the thyroid were most pronounced in the right (R) direction, while other OARs such as the heart and LAD were most pronounced in the posterior (P) direction. At a 3 mm error in the most sensitive direction, the D mean (mean dose) of the esophagus, thyroid, LAD, heart, and ipsilateral lung increased by 2.24 Gy, 1.28 Gy, 1.57 Gy, 0.26 Gy, and 0.61 Gy, respectively. When the error increased to 9 mm, these increments further rose to 7.20 Gy, 4.59 Gy, 5.60 Gy, 1.29 Gy, and 2.34 Gy.
Conclusion
The esophagus and thyroid are most sensitive to setup errors in the right direction, while the heart, LAD, and lung are most sensitive to errors in the posterior direction. It is recommended that the setup error tolerance be set at 3 mm for the CTV cw and OARs, whereas for the CTV sc may be relaxed to 5 mm.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, General Hospital of Ningxia Medical University, Yinchuan, Ningxia, China.
Zitieren
APA
Wang, P., Ma, G., Zhao, T., Ding, W., Kong, W., Ye, H., Shang, J., & Yang, W. (2026). The impact of positioning errors on the dose distribution of hypofractionated radiotherapy for left-sided radical breast cancer. Frontiers in Oncology, 16. https://doi.org/10.3389/fonc.2026.1805689
Vancouver
Wang P, Ma G, Zhao T, Ding W, Kong W, Ye H, et al. The impact of positioning errors on the dose distribution of hypofractionated radiotherapy for left-sided radical breast cancer. Frontiers in Oncology. 2026;16. doi:10.3389/fonc.2026.1805689
BibTeX
@article{Wang2026,
author = {Wang, Pan and Ma, Guofeng and Zhao, Ting and Ding, Wei and Kong, Wei and Ye, Hongqiang and Shang, Jun and Yang, Wanfu},
title = {The impact of positioning errors on the dose distribution of hypofractionated radiotherapy for left-sided radical breast cancer},
journal = {Frontiers in Oncology},
year = {2026},
volume = {16},
doi = {10.3389/fonc.2026.1805689}
}
EUVIMED