Fine needle assisted puncture positioning technique for CT-guided percutaneous interventions
Frontiers in Oncology · 12.06.2026 · 16
DOI: 10.3389/fonc.2026.1715384 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Oncology, online erschienen am 12.06.2026. Verfasst von Qingqing Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Interventional Radiology, The Affiliated Hospital of Jiangsu University, Jiangsu University, Zhenjiang, China. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
This study evaluated the feasibility and safety of a fine-needle-assisted, two-step puncture technique developed to improve accuracy in CT-guided percutaneous interventions at challenging target locations, compared with conventional approaches.
Methods
In this retrospective study, CT-guided procedures—including biopsy, preoperative localization, microwave ablation, or percutaneous vertebroplasty—were performed on 40 patients with challenging target locations. In the fine-needle-assisted group, a 20/22-gauge initial fine needle was positioned near the target under CT guidance to serve as a guide. The secondary needle —such as a coaxial biopsy needle, microwave antenna, or bone puncture needle—was then introduced along the same trajectory and angle as the fine needle. The conventional approach involved a direct, stepwise needle insertion toward the lesion in 20 patients with challenging target locations. The number of repositioning attempts for the coaxial needle, microwave ablation antenna, and bone puncture needle, as well as the puncture time, were compared between the two groups. Puncture success rates and complications were recorded.
Results
In the fine-needle-assisted group, initial fine-needle placement was successful in all 20 cases, allowing subsequent puncture of the target lesions. In the conventional approach group, one puncture failure was recorded. No major complications—such as massive pneumothorax, significant hemorrhage, or injury to major vessels or nerves—occurred in either group. The fine needle assisted group required fewer repositioning attempts and shorter puncture times than the conventional approach group, 0.9 ± 0.7 vs. 2.2 ± 1.3 times(p < 0.05) and 12.05 ± 2.86 vs. 14.95 ± 3.32 minutes(p < 0.05), respectively.
Conclusion
The fine-needle-assisted puncture technique offers a safe, feasible, and effective means of improving precision in CT-guided percutaneous procedures at challenging target locations compared with conventional approaches.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Interventional Radiology, The Affiliated Hospital of Jiangsu University, Jiangsu University, Zhenjiang, China.
Zitieren
APA
Wang, Q., Wang, H., Zhang, J., & Tan, Z. (2026). Fine needle assisted puncture positioning technique for CT-guided percutaneous interventions. Frontiers in Oncology, 16. https://doi.org/10.3389/fonc.2026.1715384
Vancouver
Wang Q, Wang H, Zhang J, Tan Z. Fine needle assisted puncture positioning technique for CT-guided percutaneous interventions. Frontiers in Oncology. 2026;16. doi:10.3389/fonc.2026.1715384
BibTeX
@article{Wang2026,
author = {Wang, Qingqing and Wang, Huanjing and Zhang, Jian and Tan, Zhongbao},
title = {Fine needle assisted puncture positioning technique for CT-guided percutaneous interventions},
journal = {Frontiers in Oncology},
year = {2026},
volume = {16},
doi = {10.3389/fonc.2026.1715384}
}
EUVIMED