EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyseOpen Access · CC BY 4.0

68Ga-PSMA-11 PET/CT versus 68Ga-PSMA-11 PET/MRI for the detection of biochemically recurrent prostate cancer: a systematic review and meta-analysis

Ruizhe Huang, Yizhen Li, Haowen Wu, Boyi Liu, Xuanjun Zhang, Zhongxi Zhang

Frontiers in Oncology · 14.08.2023 · 13

DOI: 10.3389/fonc.2023.1216894 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Frontiers in Oncology, online erschienen am 14.08.2023. Verfasst von Ruizhe Huang und 5 weiteren Autor:innen. Beteiligte Einrichtung: The First Clinical College, Changsha Medical University, Changsha, China. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Our aim was to conduct a meta-analysis and systematic review in order to compare the diagnostic efficacy of 68 Ga-PSMA-11 PET/CT and 68 Ga-PSMA-11 PET/MRI in patients with biochemically recurrent after radical prostatectomy and biochemically recurrent prostate cancers (BCR) after hybrid RT and RP.

Methods

Up until February 2023, we searched PubMed, Embase, and Web of Science for pertinent papers. Studies examining the utility of 68 Ga-PSMA-11 PET/CT or PET/MRI as a screening tool for biochemically recurrent prostate cancer were included. To measure heterogeneity, we employed the I 2 statistic. In cases of substantial heterogeneity (I 2 > 50%), we used the random effect model to produce a forest plot. In other cases, we utilized the fixed model. Furthermore, we assessed the quality of the studies included using the Quality Assessment of Diagnostic Performance Studies (QUADAS-2) method.

Results

In total, 37 studies involving 8409 patients were examined. For 68 Ga-PSMA-11 PET/CT and 68 Ga-PSMA-11 PET/MRI, the combined total detection rate was 0.70 (95% CI: 0.65-0.75) and 0.71 (95% CI:0.67-0.75), respectively. 68 Ga-PSMA-11 PET/CT and 68 Ga-PSMA-11 PET/MRI did not substantially differ in terms of the overall detection rate for BCR (P = 0.58) . The detection rate was unaffected by the PSA values (all P > 0.05) .

Conclusion

The diagnostic efficacy of 68 Ga-PSMA-11 PET/CT appears to be equivalent to that of 68 Ga-PSMA-11 PET/MRI in detecting biochemically recurrent prostate cancer. Nonetheless, it should be noted that not all studies have used pathological biopsies as the gold standard. Therefore, additional larger prospective studies are needed to address this issue. Systematic review registration identifier CRD42023410039.

Schlagwörter

Stichwörter der Autor:innen

PET/CTPET/MRIbiochemically recurrencemeta-analysisprostate cancer

Autor:innen und Institutionen

  • The First Clinical College, Changsha Medical University, Changsha, China.

Zitieren

APA

Huang, R., Li, Y., Wu, H., Liu, B., Zhang, X., & Zhang, Z. (2023). 68Ga-PSMA-11 PET/CT versus 68Ga-PSMA-11 PET/MRI for the detection of biochemically recurrent prostate cancer: a systematic review and meta-analysis. Frontiers in Oncology, 13. https://doi.org/10.3389/fonc.2023.1216894

Vancouver

Huang R, Li Y, Wu H, Liu B, Zhang X, Zhang Z. 68Ga-PSMA-11 PET/CT versus 68Ga-PSMA-11 PET/MRI for the detection of biochemically recurrent prostate cancer: a systematic review and meta-analysis. Frontiers in Oncology. 2023;13. doi:10.3389/fonc.2023.1216894

BibTeX
@article{Huang2023,
  author = {Huang, Ruizhe and Li, Yizhen and Wu, Haowen and Liu, Boyi and Zhang, Xuanjun and Zhang, Zhongxi},
  title = {68Ga-PSMA-11 PET/CT versus 68Ga-PSMA-11 PET/MRI for the detection of biochemically recurrent prostate cancer: a systematic review and meta-analysis},
  journal = {Frontiers in Oncology},
  year = {2023},
  volume = {13},
  doi = {10.3389/fonc.2023.1216894}
}
Kostenlos starten →