EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Noise-robustness test for ultrasound breast nodule neural network models as medical devices

Jiaxin Jiang, Xiaoya Jiang, Lei Xu, Yan Zhang, Yuwen Zheng, Dexing Kong

Frontiers in Oncology · 22.06.2023 · 13

DOI: 10.3389/fonc.2023.1177225 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Oncology, online erschienen am 22.06.2023. Verfasst von Jiaxin Jiang und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Mathematical Sciences, Zhejiang University, Hangzhou, China. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Deep learning technology has been widely applied to medical image analysis. But due to the limitations of its own imaging principle, ultrasound image has the disadvantages of low resolution and high Speckle Noise density, which not only hinder the diagnosis of patients’ conditions but also affect the extraction of ultrasound image features by computer technology.

Objective

In this study, we investigate the robustness of deep convolutional neural network (CNN) for classification, segmentation, and target detection of breast ultrasound image through random Salt & Pepper Noise and Gaussian Noise.

Methods

We trained and validated 9 CNN architectures in 8617 breast ultrasound images, but tested the models with noisy test set. Then, we trained and validated 9 CNN architectures with different levels of noise in these breast ultrasound images, and tested the models with noisy test set. Diseases of each breast ultrasound image in our dataset were annotated and voted by three sonographers based on their malignancy suspiciousness. we use evaluation indexes to evaluate the robustness of the neural network algorithm respectively.

Results

There is a moderate to high impact (The accuracy of the model decreased by about 5%-40%) on model accuracy when Salt and Pepper Noise, Speckle Noise, or Gaussian Noise is introduced to the images respectively. Consequently, DenseNet, UNet++ and Yolov5 were selected as the most robust model based on the selected index. When any two of these three kinds of noise are introduced into the image at the same time, the accuracy of the model will be greatly affected.

Conclusions

Our experimental results reveal new insights: The variation trend of accuracy with the noise level in Each network used for classification tasks and object detection tasks has some unique characteristics. This finding provides us with a method to reveal the black-box architecture of computer-aided diagnosis (CAD) systems. On the other hand, the purpose of this study is to explore the impact of adding noise directly to the image on the performance of neural networks, which is different from the existing articles on robustness in the field of medical image processing. Consequently, it provides a new way to evaluate the robustness of CAD systems in the future.

Schlagwörter

Stichwörter der Autor:innen

breast nodulebreast ultrasounddeep learningimage noisenetwork performance analysisrobustness

Autor:innen und Institutionen

  • School of Mathematical Sciences, Zhejiang University, Hangzhou, China.
  • Department of Mathematics, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, China.
  • Zhejiang Demetics Medical Technology Co., Ltd, Hangzhou, China.
  • Department of Interventional Therapy, The Hwa Mei Hospital of the University of Chinese Academy of Sciences, Ningbo, China.

Zitieren

APA

Jiang, J., Jiang, X., Xu, L., Zhang, Y., Zheng, Y., & Kong, D. (2023). Noise-robustness test for ultrasound breast nodule neural network models as medical devices. Frontiers in Oncology, 13. https://doi.org/10.3389/fonc.2023.1177225

Vancouver

Jiang J, Jiang X, Xu L, Zhang Y, Zheng Y, Kong D. Noise-robustness test for ultrasound breast nodule neural network models as medical devices. Frontiers in Oncology. 2023;13. doi:10.3389/fonc.2023.1177225

BibTeX
@article{Jiang2023,
  author = {Jiang, Jiaxin and Jiang, Xiaoya and Xu, Lei and Zhang, Yan and Zheng, Yuwen and Kong, Dexing},
  title = {Noise-robustness test for ultrasound breast nodule neural network models as medical devices},
  journal = {Frontiers in Oncology},
  year = {2023},
  volume = {13},
  doi = {10.3389/fonc.2023.1177225}
}
Kostenlos starten →