Evaluating the agreement of continuous glucose monitoring system with venous methods for glycemic index determination
Frontiers in Nutrition · 28.05.2026 · 13
DOI: 10.3389/fnut.2026.1842475 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Nutrition, online erschienen am 28.05.2026. Verfasst von Lihua Li und 10 weiteren Autor:innen. Beteiligte Einrichtung: Lianshui People's Hospital Affiliated to Kangda College of Nanjing Medical University, Huai'an, Jiangsu, China. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Continuous glucose monitoring systems (CGMS) are widely used in diabetes care, but their reliability for standardized food glycemic index (GI) measurement remains unclear. Most previous studies used capillary blood rather than venous glucose as the reference.
Objective
This study aimed to verify the consistency between the CGMS and standardized venous sampling methods for measuring postprandial incremental area under the curve (IAUC) and GI values.
Methods
This study was conducted in accordance with the Chinese GI testing standard WS/T 652–2019. Three measurement methods were compared: venous sampling (Method A), CGMS with all data points adopted (Method B), and CGMS data aligned with the standard venous time points (Method C). One-way analysis of variance (ANOVA) and Lin’s concordance correlation coefficient (CCC) were used for statistical analysis. The Parkes Error Grid analysis was employed to ascertain the clinical acceptability of glucose discrepancies within low, medium, and high concentration strata.
Results
The 12 enrolled participants (six males and six females) had a mean age of 29.50 ± 10.12 years, mean BMI of 21.5 ± 1.7 kg/m 2 , mean HbA1c of 5.07 ± 0.21%, and all lipid, glycemic, hepatic and renal function indicators were within normal reference ranges. For 120-min IAUC, the mean values were 186.93 ± 87.29 (Method A), 166.00 ± 76.46 (Method B) and 164.24 ± 77.48 (Method C). ANOVA showed no significant inter-method difference ( F = 1.178, p = 0.311). CCC analysis with Method A as the reference revealed good agreement: CCC = 0.8818 (95% CI: 0.8068–0.9289) for A vs. B and CCC = 0.8727 (95% CI: 0.7921–0.9234) for A vs. C, with a high Pearson’s ρ (>0.91) and bias correction factors (Cb, >0.95 fot both). For GI values (n = 12 for each method), the mean values were 55.07 ± 15.57 (Method A), 54.28 ± 12.24 (Method B) and 53.68 ± 15.04 (Method C). ANOVA showed no significant inter-method difference ( F = 0.028, p = 0.972), and CCC analysis indicated moderate agreement (CCC ≈ 0.79) with minimal systematic bias (Cb > 0.97).
Conclusion
CGMS methods demonstrate good-to-moderate concordance with standardized venous testing for IAUC and GI determination. CGMS may represent a feasible, non-invasive alternative for food GI evaluation in nutritional and diabetes-related research among healthy individuals.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Lianshui People's Hospital Affiliated to Kangda College of Nanjing Medical University, Huai'an, Jiangsu, China.
- Jiangsu Province People's Hospital, The First Affiliated Hospital with Nanjing Medical University, Nanjing, Jiangsu, China.
Zitieren
APA
Li, L., Hu, Q., Li, M., Zhao, Y., Zhang, R., Liu, Y., Tong, X., Zhu, H., Zhang, M., Zhao, Q., & Ma, X. (2026). Evaluating the agreement of continuous glucose monitoring system with venous methods for glycemic index determination. Frontiers in Nutrition, 13. https://doi.org/10.3389/fnut.2026.1842475
Vancouver
Li L, Hu Q, Li M, Zhao Y, Zhang R, Liu Y, et al. Evaluating the agreement of continuous glucose monitoring system with venous methods for glycemic index determination. Frontiers in Nutrition. 2026;13. doi:10.3389/fnut.2026.1842475
BibTeX
@article{Li2026,
author = {Li, Lihua and Hu, Qiaosheng and Li, Menglan and Zhao, Yan and Zhang, Rui and Liu, Yan and Tong, Xin and Zhu, Haiying and Zhang, Mengya and Zhao, Qing and Ma, Xianghua},
title = {Evaluating the agreement of continuous glucose monitoring system with venous methods for glycemic index determination},
journal = {Frontiers in Nutrition},
year = {2026},
volume = {13},
doi = {10.3389/fnut.2026.1842475}
}
EUVIMED