EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Deuterium oxide validation of bioimpedance total body water estimates in Hispanic adults

Grant M Tinsley, Kyung-Shin Park, Catherine Saenz, Ayush Mehra, Michael R Esco, Stefan A Czerwinski, Brett S Nickerson

Frontiers in Nutrition · 24.08.2023 · 10

DOI: 10.3389/fnut.2023.1221774 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Nutrition, online erschienen am 24.08.2023. Verfasst von Grant M Tinsley und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, United States. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To date, body composition assessments in Hispanics, computed via bioimpedance devices, have primarily focused on body fat percent, fat mass, and fat-free mass instead of total body water (TBW). Additionally, virtually no information is available on which type of bioimpedance device is preferred for TBW assessments in Hispanic populations.

Purpose

The purpose of this study was to validate two bioimpedance devices for the estimate of TBW in Hispanics adults when using a criterion deuterium oxide (D 2 O) technique.

Methods

One-hundred thirty individuals (males: n = 70; females: n = 60) of Hispanic descent had TBW estimated via D 2 O, single-frequency bioimpedance analysis ([SF-BIA] Quantum V, RJL Systems) and bioimpedance spectroscopy ([BIS] SFB7 Impedimed).

Results

The mean values for SF-BIA were significantly lower than D 2 O when evaluating the entire sample (37.4 L and 38.2 L, respectively; p < 0.05). In contrast, TBW values were not statistically significant when comparing D 2 O against BIS (38.4 L, p > 0.05). Bland–Altman analysis indicated no proportional bias when evaluating the entire sample for SF-BIA or BIS. The standard error of estimate and total error values were ≤ 2.3 L and Lin’s concordance correlation coefficient were ≥ 0.96 for all comparisons.

Conclusion

The SF-BIA and BIS devices evaluated in the current study hold promise for accurate estimation of TBW in Hispanic adults. While both methods demonstrated relatively low errors relative to the D 2 O criterion, BIS exhibited a more consistent performance, particularly at the group level. These findings provide essential information for researchers and clinical nutrition practitioners assessing TBW in Hispanic adults.

Schlagwörter

Stichwörter der Autor:innen

BIAbody compositiondilutionfat-free masshydrationlean mass

Autor:innen und Institutionen

  • Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, TX, United States.
  • College of Nursing and Health Sciences, Texas A&M International University, Laredo, TX, United States.
  • Department of Human Science, The Ohio State University, Columbus, OH, United States.
  • Department of Kinesiology, University of Alabama, Tuscaloosa, AL, United States.
  • School of Health and Rehabilitation Sciences, The Ohio State University, Columbus, OH, United States.

Zitieren

APA

Tinsley, G. M., Park, K. S., Saenz, C., Mehra, A., Esco, M. R., Czerwinski, S. A., & Nickerson, B. S. (2023). Deuterium oxide validation of bioimpedance total body water estimates in Hispanic adults. Frontiers in Nutrition, 10. https://doi.org/10.3389/fnut.2023.1221774

Vancouver

Tinsley GM, Park KS, Saenz C, Mehra A, Esco MR, Czerwinski SA, et al. Deuterium oxide validation of bioimpedance total body water estimates in Hispanic adults. Frontiers in Nutrition. 2023;10. doi:10.3389/fnut.2023.1221774

BibTeX
@article{Tinsley2023,
  author = {Tinsley, Grant M and Park, Kyung-Shin and Saenz, Catherine and Mehra, Ayush and Esco, Michael R and Czerwinski, Stefan A and Nickerson, Brett S},
  title = {Deuterium oxide validation of bioimpedance total body water estimates in Hispanic adults},
  journal = {Frontiers in Nutrition},
  year = {2023},
  volume = {10},
  doi = {10.3389/fnut.2023.1221774}
}
Kostenlos starten →