Transcranial alternating current stimulation (tACS) above individual peak alpha frequency (PAF) does not shift PAF or experimental pain sensitivity: an exploratory study
Frontiers in Human Neuroscience · 07.07.2026 · 20
DOI: 10.3389/fnhum.2026.1851160 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Human Neuroscience, online erschienen am 07.07.2026. Verfasst von Irit Weissman-Fogel und 4 weiteren Autor:innen. Beteiligte Einrichtung: Sensory Neuroscience and Pain Laboratory, Physical Therapy Department, Faculty of Social Welfare and Health Sciences, University of Haifa, Haifa, Isr…. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Peak alpha frequency (PAF) is negatively associated with experimental pain sensitivity. Transcranial alternating current stimulation (tACS) enables shifting neural frequency to modulate sensory perception, yet it has not been tested in pain perception. We hypothesized that tACS application at 1 Hz above the individual PAF (iPAF) would increase PAF and reduce experimental pain ratings.
Methods
This is a double-blind, sham-controlled, crossover, exploratory study with 15 healthy participants who completed 2 sessions; 20 min of tACS was applied to the somatosensory cortex at 1 Hz above the iPAF or sham stimulation (Intervention), administered in random order. Pain reports (4 time points) in response to a tonic heat pain (THP) stimulus were recorded before and after tACS. Five-minute electroencephalography was recorded in 4 conditions: baseline (iPAF identification), after THP stimulus, after tACS to test its effect on iPAF, and after another THP stimulus to test pain effects on iPAF following tACS. This paradigm examines associations between iPAF and pain, and the effects of pain and tACS on iPAF.
Results
There was no effect of real vs. sham tACS on iPAF, with a non-significant Condition × Intervention interaction and a small effect size (partial η 2 0.01 and 0.03). Pain intensity increased across rating time points ( p < 0.001), but tACS had no effects.
Discussion
In this small-sample preliminary study, a single tACS session did not affect iPAF or pain ratings in response to THP stimulus. The current study may help shape methodologies for future pain studies investigating the effects of tACS on PAF and pain.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sensory Neuroscience and Pain Laboratory, Physical Therapy Department, Faculty of Social Welfare and Health Sciences, University of Haifa, Haifa, Israel.
- Department of Neurosurgery, Rambam Health Care Center, Haifa, Israel.
- Department of Neurology, Rambam Health Care Center, Haifa, Israel.
- The Laboratory of Clinical Neurophysiology, Bruce Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel.
- The Clinical Pain Innovation Laboratory, The Cheryl Spencer Department of Nursing, Faculty of Social Welfare and Health Sciences, University of Haifa, Haifa, Israel.
Zitieren
APA
Weissman-Fogel, I., Sheban, R., Sinai, A., Granovsky, Y., & Treister, R. (2026). Transcranial alternating current stimulation (tACS) above individual peak alpha frequency (PAF) does not shift PAF or experimental pain sensitivity: an exploratory study. Frontiers in Human Neuroscience, 20. https://doi.org/10.3389/fnhum.2026.1851160
Vancouver
Weissman-Fogel I, Sheban R, Sinai A, Granovsky Y, Treister R. Transcranial alternating current stimulation (tACS) above individual peak alpha frequency (PAF) does not shift PAF or experimental pain sensitivity: an exploratory study. Frontiers in Human Neuroscience. 2026;20. doi:10.3389/fnhum.2026.1851160
BibTeX
@article{WeissmanFogel2026,
author = {Weissman-Fogel, Irit and Sheban, Reem and Sinai, Alon and Granovsky, Yelena and Treister, Roi},
title = {Transcranial alternating current stimulation (tACS) above individual peak alpha frequency (PAF) does not shift PAF or experimental pain sensitivity: an exploratory study},
journal = {Frontiers in Human Neuroscience},
year = {2026},
volume = {20},
doi = {10.3389/fnhum.2026.1851160}
}
EUVIMED