EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyseOpen Access · CC BY 4.0

The effects of repetitive transcranial magnetic and transcranial direct current stimulation on memory functions in older adults with mild cognitive impairment: a systematic review and meta-analysis

Auswirkungen von repetitiver transkranieller Magnetstimulation und transkranieller Gleichstromstimulation auf Gedächtnisfunktionen bei älteren Erwachsenen mit milder kognitiver Beeinträchtigung: systematische Übersicht und Metaanalyse

Mengdie Hu, Michael A Nitsche, Yanxin Lv, Hairong Han, Xu Lin, Fengxue Qi

Frontiers in Human Neuroscience · 13.08.2024 · 18

DOI: 10.3389/fnhum.2024.1436448 ↗

Auf einen Blick

11 Studien mit 406 Patient:innen zeigen eine Verbesserung der Gedächtnisfunktionen unter rTMS und tDCS. rTMS wirkte insgesamt stärker als tDCS.

Fragestellung

Wie wirken rTMS und tDCS auf Gedächtnisfunktionen bei Patient:innen mit milder kognitiver Beeinträchtigung?

Methode

Systematische Übersicht und Metaanalyse von 11 Studien; Suche in 8 Datenbanken bis 16. März 2024; Effektstärke als SMD mit 95 %-KI.

Ergebnisse

rTMS und tDCS verbesserten die Gedächtnisfunktion (SMD 0,61; 95 %-KI 0,41–0,82; p < 0,00001; I² = 22 %). rTMS war in Subgruppenanalysen wirksamer als tDCS. Nebenwirkungen traten häufiger auf (RR 3,18; 95 %-KI 1,29–7,83).

Einschränkungen

Für tDCS konnten wegen unzureichender Daten keine Parameter festgelegt werden.

Schlussfolgerung der Autor:innen

Die Autor:innen schlussfolgern, dass rTMS und tDCS sichere und wirksame Verfahren zur Verbesserung der Gedächtnisfunktionen bei MCI sind; rTMS zeigte den größeren Effekt.

Kernaussagen

  • Gedächtnis: SMD 0,61 zugunsten von rTMS und tDCS
  • rTMS zeigte in Subgruppenanalysen die stärkere Wirkung
  • Temporäre Nebenwirkungen traten unter rTMS häufiger auf (RR 3,18)

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Systematische Übersicht in der Zeitschrift Frontiers in Human Neuroscience, online erschienen am 13.08.2024. Verfasst von Mengdie Hu und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Sports Medicine and Rehabilitation, Beijing Sport University, Beijing, China. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Mild cognitive impairment (MCI) is a condition that impairs activities of daily living, and often transforms to dementia. Repetitive transcranial magnetic stimulation (rTMS) and transcranial direct current stimulation (tDCS) show promise in improving cognitive functions in MCI patients. In this meta-analysis, we aimed to compare the effects of rTMS and tDCS on memory functions in MCI patients. We explored eight databases from their inception to March 16, 2024. We obtained 11 studies with 406 patients with MCI. We used the standardized mean difference (SMD) with a 95% confidence interval (CI) to synthesize the effect size. rTMS and tDCS significantly improved memory functions in MCI patients (SMD = 0.61; 95% CI: 0.41–0.82; p < 0.00001; I 2 = 22%). In subgroup analysis of number of stimulation sessions, both rTMS and tDCS over 10 sessions (SMD = 0.84; 95% CI: 0.50–1.17, p < 0.00001, I 2 = 0%) significantly improved the memory function in MCI patients. The subgroup analyses on different stimulation types (SMD = 0.78; 95% CI: 0.51–1.06; p < 0.00001; I 2 = 0%) and treatment persistent effects (SMD = 0.93; 95% CI: 0.51–1.35, p < 0.0001, I 2 = 0%) showed that rTMS was more effective than tDCS. rTMS with a stimulation frequency of 10 Hz (SMD = 0.86; 95% CI: 0.51–1.21; p < 0.00001; I 2 = 0%) and over 10 sessions (SMD = 0.98; 95% CI: 0.58–1.38; p < 0.00001; I 2 = 0%) at multiple sites (SMD = 0.97; 95% CI: 0.44–1.49; p = 0.0003; I 2 = 0%) showed a great improvement in the memory performance of patients with MCI. rTMS was more likely to appear temporary side effects (risk ratio (RR) = 3.18, 95% CI: 1.29–7.83, p = 0.01). This meta-analysis suggests that rTMS and tDCS are safe and efficient tools to improve memory functions in patients with MCI, while rTMS had a larger effect than tDCS. rTMS with a stimulation frequency of 10 Hz targeted on multiple sites over 10 sessions showed the greatest effect. We could not conclude parameters of tDCS because of insufficient data. Systematic Review Registration https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42024558991 .

Schlagwörter

Stichwörter der Autor:innen

cognitive functionmemorymild cognitive impairmentnon-invasive brain stimulationrepetitive transcranial magnetic stimulationtranscranial direct current stimulation

Autor:innen und Institutionen

  • School of Sports Medicine and Rehabilitation, Beijing Sport University, Beijing, China.
  • Department of Psychology and Neurosciences, Leibniz Research Center for Working Environment and Human Factors, Dortmund, Germany.
  • University Clinic of Psychiatry and Psychotherapy, Protestant Hospital of Bethel Foundation, University Hospital OWL, Bielefeld University, Bielefeld, Germany.
  • German Center for Mental Health (DZPG), Bochum, Germany.
  • Sports, Exercise and Brain Sciences Laboratory, Sports Coaching College, Beijing Sport University, Beijing, China.
  • Blood Purification Department, The Eighth People's Hospital of Jinan, Shandong, China.

Zitieren

APA

Hu, M., Nitsche, M. A., Lv, Y., Han, H., Lin, X., & Qi, F. (2024). The effects of repetitive transcranial magnetic and transcranial direct current stimulation on memory functions in older adults with mild cognitive impairment: a systematic review and meta-analysis. Frontiers in Human Neuroscience, 18. https://doi.org/10.3389/fnhum.2024.1436448

Vancouver

Hu M, Nitsche MA, Lv Y, Han H, Lin X, Qi F. The effects of repetitive transcranial magnetic and transcranial direct current stimulation on memory functions in older adults with mild cognitive impairment: a systematic review and meta-analysis. Frontiers in Human Neuroscience. 2024;18. doi:10.3389/fnhum.2024.1436448

BibTeX
@article{Hu2024,
  author = {Hu, Mengdie and Nitsche, Michael A and Lv, Yanxin and Han, Hairong and Lin, Xu and Qi, Fengxue},
  title = {The effects of repetitive transcranial magnetic and transcranial direct current stimulation on memory functions in older adults with mild cognitive impairment: a systematic review and meta-analysis},
  journal = {Frontiers in Human Neuroscience},
  year = {2024},
  volume = {18},
  doi = {10.3389/fnhum.2024.1436448}
}
Kostenlos starten →