EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY 4.0

Dual-target VIM–PSA deep brain stimulation using octopolar electrodes: surgical technique and feasibility study

Lucía Triguero-Cueva, José Pablo Martínez-Barbero, Carlos Javier Madrid-Navarro, María José Pérez-Navarro, Adolfo Mínguez-Castellanos, Bartolomé Marín-Romero, Benjamín Iáñez-Velasco, Francisco Escamilla-Sevilla, Majed Jouma Katati

Frontiers in Neurology · 05.08.2026 · 17

DOI: 10.3389/fneur.2026.1865673 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Frontiers in Neurology, online erschienen am 05.08.2026. Verfasst von Lucía Triguero-Cueva und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Hospital Universitario Virgen de las Nieves, Granada, Spain. Hauptthemen laut MEDLINE: Deep Brain Stimulation, Essential Tremor, Electrodes, Implanted, Subthalamic Nucleus. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/objectives Deep brain stimulation (DBS) is an established surgical treatment for essential tremor (ET). Both the thalamic ventral intermediate nucleus (VIM) and the posterior subthalamic area (PSA) are effective tremor targets can be approached through a single trajectory. This technical feasibility report describes a single-trajectory dual-target VIM–PSA DBS surgical protocol using octopolar electrodes and evaluates stereotactic accuracy, anatomical contact distribution, and preliminary surgical safety.

Methods

Eleven patients with medication-refractory ET underwent bilateral DBS implantation within the framework of an ongoing randomized, double-blind, crossover clinical trial comparing VIM-DBS and PSA-DBS. Preoperative planning was performed using Brainlab Elements, and postoperative reconstruction was performed using Guide™ XT after fusion of preoperative MRI with one-month postoperative CT. Clinical and electrical data (efficacy outcomes, stimulation thresholds, side-effect thresholds, active contact selection, energy consumption, habituation, patient-reported outcomes, and programming burden) were not assessed in this report.

Results

A total of 22 octopolar DBS leads were implanted. Postoperative reconstruction confirmed anatomical contact distribution across the reconstructed VIM model and the PSA/cZI target region. Mean planned-to-implanted deviation across contacts was 1.28 mm for the left electrodes and 1.50 mm for the right electrodes. One patient developed transient symptomatic perielectrode edema; no intracerebral hemorrhage or any other major surgery-related adverse event was observed during early postoperative follow-up.

Conclusion

Single-trajectory dual-target VIM–PSA DBS using octopolar electrodes was successfully performed with acceptable stereotactic accuracy and without major surgery-related adverse events in this small cohort. The approach may increase anatomical coverage and postoperative programming options. Clinical data remain to be determined.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep Brain StimulationEssential TremorElectrodes, ImplantedSubthalamic NucleusVentral Thalamic NucleiHumansFeasibility StudiesFemaleMaleAgedDouble-Blind MethodMiddle AgedCross-Over Studies

Stichwörter der Autor:innen

deep brain stimulationdentato-rubro-thalamic tractdouble-targetessential tremoroctopolar electrodesposterior subthalamic areaventral intermediate nucleus

Autor:innen und Institutionen

  • Department of Neurology, Hospital Universitario Virgen de las Nieves, Granada, Spain.
  • IInstituto de Investigación Biosanitaria ibs. GRANADA, Granada, Spain.
  • Department of Neuroradiology, Hospital Universitario Virgen de las Nieves, Granada, Spain.
  • Neuropsychology, Hospital Universitario Virgen de las Nieves, Granada, Spain.
  • Department of Neurosurgery, Hospital Universitario Virgen de las Nieves, Granada, Spain.
  • Department of Surgery, Faculty of Medicine, Granada University, Granada, Spain.

Zitieren

APA

Triguero-Cueva, L., Martínez-Barbero, J. P., Madrid-Navarro, C. J., Pérez-Navarro, M. J., Mínguez-Castellanos, A., Marín-Romero, B., Iáñez-Velasco, B., Escamilla-Sevilla, F., & Katati, M. J. (2026). Dual-target VIM–PSA deep brain stimulation using octopolar electrodes: surgical technique and feasibility study. Frontiers in Neurology, 17. https://doi.org/10.3389/fneur.2026.1865673

Vancouver

Triguero-Cueva L, Martínez-Barbero JP, Madrid-Navarro CJ, Pérez-Navarro MJ, Mínguez-Castellanos A, Marín-Romero B, et al. Dual-target VIM–PSA deep brain stimulation using octopolar electrodes: surgical technique and feasibility study. Frontiers in Neurology. 2026;17. doi:10.3389/fneur.2026.1865673

BibTeX
@article{TrigueroCueva2026,
  author = {Triguero-Cueva, Lucía and Martínez-Barbero, José Pablo and Madrid-Navarro, Carlos Javier and Pérez-Navarro, María José and Mínguez-Castellanos, Adolfo and Marín-Romero, Bartolomé and Iáñez-Velasco, Benjamín and Escamilla-Sevilla, Francisco and Katati, Majed Jouma},
  title = {Dual-target VIM–PSA deep brain stimulation using octopolar electrodes: surgical technique and feasibility study},
  journal = {Frontiers in Neurology},
  year = {2026},
  volume = {17},
  doi = {10.3389/fneur.2026.1865673}
}
Kostenlos starten →