EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Diagnostic accuracy of transcranial sonography-magnetic resonance fusion imaging for Parkinson’s disease versus multiple system atrophy—Parkinsonian type

Chao Hou, Wei Zhang, Ji-Zhu Xia, Hui Liu, Ming-Xing Li, Wen He, Li-Qing Peng

Frontiers in Neurology · 22.04.2026 · 17

DOI: 10.3389/fneur.2026.1797261 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Neurology, online erschienen am 22.04.2026. Verfasst von Chao Hou und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, the Affiliated Hospital, Southwest Medical University, Luzhou, Sichuan, China. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Transcranial sonography-magnetic resonance (TCS-MR) fusion imaging shows promise in neurodegenerative diseases, yet current echogenicity assessment methods remain controversial, and its role in differentiating Parkinson’s disease (PD) from multiple system atrophy-parkinsonian type (MSA-P) remains unknown.

Objectives

This study aims to evaluate the diagnostic and differential value of TCS-MR fusion imaging for PD versus MSA-P. Patients and methods 164 PD, 71 MSA-P, and 118 controls who underwent TCS-MR fusion imaging were prospectively enrolled. Substantia nigra hyperechogenicity (SNH) area was calculated. Three planes, designated as SN1, SN2 and SN3 from fusion images were analyzed using ImageJ for grayscale median and pixel count. ROC curves were employed to assess diagnostic and differential diagnostic power.

Results

Statistically significant differences were observed among the three groups concerning SN grades, area of SNH, the ratio of the area of SNH to the midbrain area (S/M), echogenicity of the bilateral SN1, SN3, left SNH, and the maximum echogenicity of SN1, as well as the pixel count of bilateral SNH ( p < 0.05). The maximum echogenicity of SN1 and left SN1 demonstrated the highest diagnostic and differential performance for PD, with AUC values of 0.86 and 0.82 (both p < 0.001). Fusion parameters outperformed the SNH area and S/M in both diagnosis and differential diagnosis of PD (Z = 3.84 and 3.71, p < 0.01).

Conclusion

TCS-MR fusion imaging demonstrates superior diagnostic and differential performance for PD compared to traditional TCS measurements, suggesting its potential as a novel imaging technique in the diagnosis of PD.

Schlagwörter

Stichwörter der Autor:innen

Parkinson’s diseasefusion imagingmultiple system atrophysubstantia nigratranscranial sonography

Autor:innen und Institutionen

  • Department of Ultrasound, the Affiliated Hospital, Southwest Medical University, Luzhou, Sichuan, China.
  • Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.

Zitieren

APA

Hou, C., Zhang, W., Xia, J. Z., Liu, H., Li, M. X., He, W., & Peng, L. Q. (2026). Diagnostic accuracy of transcranial sonography-magnetic resonance fusion imaging for Parkinson’s disease versus multiple system atrophy—Parkinsonian type. Frontiers in Neurology, 17. https://doi.org/10.3389/fneur.2026.1797261

Vancouver

Hou C, Zhang W, Xia JZ, Liu H, Li MX, He W, et al. Diagnostic accuracy of transcranial sonography-magnetic resonance fusion imaging for Parkinson’s disease versus multiple system atrophy—Parkinsonian type. Frontiers in Neurology. 2026;17. doi:10.3389/fneur.2026.1797261

BibTeX
@article{Hou2026,
  author = {Hou, Chao and Zhang, Wei and Xia, Ji-Zhu and Liu, Hui and Li, Ming-Xing and He, Wen and Peng, Li-Qing},
  title = {Diagnostic accuracy of transcranial sonography-magnetic resonance fusion imaging for Parkinson’s disease versus multiple system atrophy—Parkinsonian type},
  journal = {Frontiers in Neurology},
  year = {2026},
  volume = {17},
  doi = {10.3389/fneur.2026.1797261}
}
Kostenlos starten →