EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of surface characteristics of implant materials on MRSA biofilm formation and effects of antimicrobial treatment

Sven C J van Dun, Mariëlle Verheul, Bart G C W Pijls, Joffrey van Prehn, Henk Scheper, Federica Galli, Peter H Nibbering, Mark G J de Boer

Frontiers in Microbiology · 20.04.2023 · 14

DOI: 10.3389/fmicb.2023.1145210 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Microbiology, online erschienen am 20.04.2023. Verfasst von Sven C J van Dun und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Infectious Diseases, Leiden University Medical Center, Leiden, Netherlands. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Leids Universitair Medisch Centrum.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

One of the main causes of treatment failure in bacterial prosthetic joint infections (PJI) is biofilm formation. The topography of the biofilm may be associated with susceptibility to antimicrobial treatment. The aims of this study were to assess differences in topography of biofilms on different implant materials and the correlation thereof with susceptibility to antimicrobial treatment.

Methods

Methicillin-resistant Staphylococcus aureus (MRSA) 7-day mature biofilms were generated on disks made from titanium alloys (Ti-6Al-7Nb and Ti-6Al-4V), synthetic polymer and orthopedic bone cement, commonly used in implant surgery. The surface topography of these implant materials and the biofilms cultured on them was assessed using atomic force microscopy. This provided detailed images, as well as average roughness (Ra) and peak-to-valley roughness (Rt) values in nanometers, of the biofilm and the material surfaces. Bacterial counts within biofilms were assessed microbiologically. Antimicrobial treatment of biofilms was performed by 24-h exposure to the combination of rifampicin and ciprofloxacin in concentrations of 1-, 5- and 10-times the minimal bactericidal concentration (MBC). Finally, treatment-induced differences in bacterial loads and their correlation with biofilm surface parameters were assessed.

Results

The biofilm surfaces on titanium alloys Ti-6Al-7Nb (Ra = 186 nm) and Ti-6Al-4V (Ra = 270 nm) were less rough than those of biofilms on silicone (Ra = 636 nm). The highest roughness was observed for biofilms on orthopedic bone cement with an Ra of 1,551 nm. Interestingly, the roughness parameters of the titanium alloys themselves were lower than the value for silicone, whereas the surface of the bone cement was the roughest. Treatment with 1- and 5-times the MBC of antibiotics resulted in inter-material differences in colony forming units (CFU) counts, ultimately showing comparable reductions of 2.4–3.0 log CFU/mL at the highest tested concentration. No significant differences in bacterial loads within MRSA biofilms were observed between the various implant materials, upon exposure to increasing concentrations of antibiotics.

Discussion

The surface parameters of MRSA biofilms were determined by those of the implant materials on which they were formed. The antibiotic susceptibility of MRSA biofilms on the various tested implant materials did not differ, indicating that the efficacy of antibiotics was not affected by the roughness of the biofilm.

Schlagwörter

Stichwörter der Autor:innen

MRSAPJIStaphylococcus aureusatomic force microscopy (AFM)biofilm

Autor:innen und Institutionen

  • Department of Infectious Diseases, Leiden University Medical Center, Leiden, Netherlands.
  • Department of Orthopedics, Leiden University Medical Center, Leiden, Netherlands.
  • Department of Medical Microbiology, Leiden University Medical Center, Leiden, Netherlands.
  • Leiden Institute of Physics, Leiden, Netherlands.

Förderung

  • Leids Universitair Medisch Centrum

Zitieren

APA

van Dun, S. C. J., Verheul, M., Pijls, B. G. C. W., van Prehn, J., Scheper, H., Galli, F., Nibbering, P. H., & de Boer, M. G. J. (2023). Influence of surface characteristics of implant materials on MRSA biofilm formation and effects of antimicrobial treatment. Frontiers in Microbiology, 14. https://doi.org/10.3389/fmicb.2023.1145210

Vancouver

van Dun SCJ, Verheul M, Pijls BGCW, van Prehn J, Scheper H, Galli F, et al. Influence of surface characteristics of implant materials on MRSA biofilm formation and effects of antimicrobial treatment. Frontiers in Microbiology. 2023;14. doi:10.3389/fmicb.2023.1145210

BibTeX
@article{vanDun2023,
  author = {van Dun, Sven C J and Verheul, Mariëlle and Pijls, Bart G C W and van Prehn, Joffrey and Scheper, Henk and Galli, Federica and Nibbering, Peter H and de Boer, Mark G J},
  title = {Influence of surface characteristics of implant materials on MRSA biofilm formation and effects of antimicrobial treatment},
  journal = {Frontiers in Microbiology},
  year = {2023},
  volume = {14},
  doi = {10.3389/fmicb.2023.1145210}
}
Kostenlos starten →