EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Bridging the gap between simulation and reality: a novel chicken breast model for peripheral intravenous cannulation training

Ulrich Steinwandel, Eden McCrystal, Lena Sloan

Frontiers in Medicine · 20.11.2026 · 13

DOI: 10.3389/fmed.2026.1954236 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Medicine, online erschienen am 20.11.2026. Verfasst von Ulrich Steinwandel und 2 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Peripheral intravenous cannulation (PIVC) is a fundamental clinical skill required for the safe administration of fluids and medications; however, traditional rubber manikin intravenous training arms, typically constructed from rigid plastic and thick rubber tubing, do not adequately replicate the tactile properties, vein elasticity, and tissue resistance of human vasculature. This limited realism may reduce learners’ ability to transfer psychomotor skills into clinical practice and negatively affect confidence during initial patient encounters. To address these limitations, a low-cost, biologically based vascular access simulation model was developed and evaluated. This was achieved using a raw, skin-on chicken breast with fluid-filled modelling balloons (approximately 6 mm in diameter) inserted subcutaneously to simulate veins. Balloons were threaded beneath the skin using a crochet needle to mimic anatomical positioning and secured with cling film before placement on a tray to maintain structural stability. The model was incorporated into a half-day PIVC workshop combining theoretical instruction with supervised hands-on practice. Across workshops conducted in 2022 and 2025, participants reported that the model provided a realistic haptic experience, closely approximating the texture, vessel elasticity, and resistance encountered in human tissue. Learners highlighted the presence of palpable, compressible “bouncy” vessels, realistic cannula penetration with minimal excessive force, and improved visualization of vessel depth and trajectory. Overall, this approach represents a cost-effective and practical alternative to conventional plastic training arms and may enhance learner engagement, perceived realism, confidence, and technical skill acquisition in vascular access education.

Zitieren

APA

Steinwandel, U., McCrystal, E., & Sloan, L. (2026). Bridging the gap between simulation and reality: a novel chicken breast model for peripheral intravenous cannulation training. Frontiers in Medicine, 13. https://doi.org/10.3389/fmed.2026.1954236

Vancouver

Steinwandel U, McCrystal E, Sloan L. Bridging the gap between simulation and reality: a novel chicken breast model for peripheral intravenous cannulation training. Frontiers in Medicine. 2026;13. doi:10.3389/fmed.2026.1954236

BibTeX
@article{Steinwandel2026,
  author = {Steinwandel, Ulrich and McCrystal, Eden and Sloan, Lena},
  title = {Bridging the gap between simulation and reality: a novel chicken breast model for peripheral intravenous cannulation training},
  journal = {Frontiers in Medicine},
  year = {2026},
  volume = {13},
  doi = {10.3389/fmed.2026.1954236}
}
Kostenlos starten →