EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Skeleton-based rehabilitation movement quality classification: a leakage-controlled benchmark on IntelliRehabDS

Zhen Zhu, Yuqiong Xiang, Xianzhu Tian

Frontiers in Medicine · 15.07.2026 · 13

DOI: 10.3389/fmed.2026.1878438 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Medicine, online erschienen am 15.07.2026. Verfasst von Zhen Zhu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, Jiujiang Hospital of Traditional Chinese Medicine, Jiujiang, Jiangxi, China. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Automated, objective assessment of rehabilitation movement quality from three-dimensional skeleton recordings can support scalable and low-cost physiotherapy monitoring, but reported performance is often affected by subject leakage, inconsistent class-imbalance handling and non-comparable evaluation protocols.

Methods

This study establishes a leakage-controlled, subject-independent benchmark on the publicly available IntelliRehabDS corpus. After removing 12 ambiguous-label files and 2 sequences shorter than 16 frames, 2,575 sequences from 29 adult and adolescent participants were retained, comprising 2,047 correct and 528 incorrect executions across nine rehabilitation gestures. Sequences were root-centred, torso-scaled, smoothed with a Savitzky–Golay filter, resampled to 64 frames and represented through kinematic features or skeleton tensors. Five classical feature-based learners and the topology-aware ST-SkelNet sequence model were evaluated through nested subject-wise cross-validation. Scaling and SMOTE were fitted only within the relevant training partitions for the classical models, whereas ST-SkelNet used class-weighted binary cross-entropy.

Results

Performance was reported using fold-averaged metrics, pooled out-of-fold confusion matrices and ROC-AUC analysis. No single model dominated: the multilayer perceptron achieved the highest accuracy (0.869), the random forest the highest ROC-AUC (0.861), and the support vector machine the highest incorrect-class recall (0.629). ST-SkelNet achieved 0.846 accuracy, 0.855 ROC-AUC and 0.612 incorrect-class recall, but did not consistently exceed the strongest classical baselines. Head-motion and bilateral-asymmetry features showed descriptive separation between correct and incorrect executions in this adult/adolescent cohort.

Discussion

The contribution is a reproducible methodological benchmark rather than a clinical system or a state-of-the-art architecture. IntelliRehabDS is treated here as a surrogate adult/adolescent dataset for methodological validation and benchmarking, not as infant data. Transfer to paediatric populations, including congenital muscular torticollis, requires independently collected age-specific data and prospective clinical validation.

Schlagwörter

Stichwörter der Autor:innen

IntelliRehabDSclass imbalancedata leakagemachine learning benchmarkingrehabilitation movement classificationskeleton-based action quality assessmentsubject-independent evaluation

Autor:innen und Institutionen

  • Department of Orthopedics, Jiujiang Hospital of Traditional Chinese Medicine, Jiujiang, Jiangxi, China.
  • School of Rehabilitation Medicine, Gannan Medical University, Ganzhou, Jiangxi, China.

Zitieren

APA

Zhu, Z., Xiang, Y., & Tian, X. (2026). Skeleton-based rehabilitation movement quality classification: a leakage-controlled benchmark on IntelliRehabDS. Frontiers in Medicine, 13. https://doi.org/10.3389/fmed.2026.1878438

Vancouver

Zhu Z, Xiang Y, Tian X. Skeleton-based rehabilitation movement quality classification: a leakage-controlled benchmark on IntelliRehabDS. Frontiers in Medicine. 2026;13. doi:10.3389/fmed.2026.1878438

BibTeX
@article{Zhu2026,
  author = {Zhu, Zhen and Xiang, Yuqiong and Tian, Xianzhu},
  title = {Skeleton-based rehabilitation movement quality classification: a leakage-controlled benchmark on IntelliRehabDS},
  journal = {Frontiers in Medicine},
  year = {2026},
  volume = {13},
  doi = {10.3389/fmed.2026.1878438}
}
Kostenlos starten →