EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Low bacterial contamination rate in platelet components following primary culture screening: a Saudi Arabian experience

Mohammed Battah Alenazi, Muhammad Raihan Sajid, Salman Aldosari, Abdulwahab Binjomah, Jana H Husein, Rasha M Khayata, Liyan Afaneh, Badr Elwy

Frontiers in Medicine · 29.07.2026 · 13

DOI: 10.3389/fmed.2026.1865609 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Medicine, online erschienen am 29.07.2026. Verfasst von Mohammed Battah Alenazi und 7 weiteren Autor:innen. Beteiligte Einrichtung: College of Medicine, Alfaisal University, Riyadh, Saudi Arabia. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Platelet storage at room temperature (20–24° C) with agitation facilitates bacterial proliferation. Despite global standards for culture-based screening, there is a lack of component-level contamination data within the Saudi Arabian context.

Methods

We conducted a retrospective review of 28,416 post-donation platelet components at the Riyadh regional laboratory (2020–2021) to determine the culture-confirmed bacterial contamination rate. Screening for bacterial contamination utilized the BacT/ALERT ® VIRTUO system at 24 ± 2 h post-collection. The primary outcome was to measure the confirmed contamination rate per 1,000 components; secondary outcomes included the positive predictive value (PPV) of initial screening and organism distribution. Screen-positive units were quarantined and underwent a formal confirmation algorithm via repeat culture and subculture.

Results

Out of 28,416 components, 49 (0.17%) were initially screen-positive. Twenty-five cases were culture-confirmed, yielding a contamination rate of 0.88 per 1,000 components (95% CI: 0.54–1.23) and a Positive Predictive Value (PPV) of 51.0%. Skin commensals predominated, led by Staphylococcus epidermidis (28.0%) and Corynebacterium spp. (16.0%).

Conclusion

The confirmed contamination rate aligns with international benchmarks for primary culture programs. These findings suggest that implementing advanced strategies like Large-Volume Delayed Sampling (LVDS) or near-issue secondary testing could further reduce the residual risk posed by slow-growing skin flora.

Schlagwörter

Stichwörter der Autor:innen

BacT/ALERT VIRTUOSaudi Arabiabacterial contaminationculture-confirmedhemovigilanceplateletspositive predictive value (PPV)

Autor:innen und Institutionen

  • College of Medicine, Alfaisal University, Riyadh, Saudi Arabia.
  • Riyadh Central Blood Bank, Blood Transfusion Service, Health Support Service Center, MOH, Riyadh, Saudi Arabia.
  • Department of Pathology, College of Medicine, Alfaisal University, Riyadh, Saudi Arabia.
  • Bacterial Diseases and Special Pathogens Department, Public Health Authority, Riyadh, Saudi Arabia.

Zitieren

APA

Alenazi, M. B., Sajid, M. R., Aldosari, S., Binjomah, A., Husein, J. H., Khayata, R. M., Afaneh, L., & Elwy, B. (2026). Low bacterial contamination rate in platelet components following primary culture screening: a Saudi Arabian experience. Frontiers in Medicine, 13. https://doi.org/10.3389/fmed.2026.1865609

Vancouver

Alenazi MB, Sajid MR, Aldosari S, Binjomah A, Husein JH, Khayata RM, et al. Low bacterial contamination rate in platelet components following primary culture screening: a Saudi Arabian experience. Frontiers in Medicine. 2026;13. doi:10.3389/fmed.2026.1865609

BibTeX
@article{Alenazi2026,
  author = {Alenazi, Mohammed Battah and Sajid, Muhammad Raihan and Aldosari, Salman and Binjomah, Abdulwahab and Husein, Jana H and Khayata, Rasha M and Afaneh, Liyan and Elwy, Badr},
  title = {Low bacterial contamination rate in platelet components following primary culture screening: a Saudi Arabian experience},
  journal = {Frontiers in Medicine},
  year = {2026},
  volume = {13},
  doi = {10.3389/fmed.2026.1865609}
}
Kostenlos starten →