Impact of closed-system suctioning on self-reported dyspnea in mechanically ventilated patients: a prospective observational study
Frontiers in Medicine · 23.06.2026 · 13
DOI: 10.3389/fmed.2026.1834389 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Medicine, online erschienen am 23.06.2026. Verfasst von Lijun Liang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Intensive Care Unit, Mianyang Central Hospital, School of Medicine, University of Electronic Science and Technology of China, Mianyang, Sichuan, Chin…. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Endotracheal suctioning is an essential airway care procedure in mechanically ventilated patients, yet its acute impact on subjective respiratory distress has not been systematically quantified.
Methods
In this prospective self-controlled observational study conducted from May to October 2025 in a tertiary intensive care unit (ICU) in Sichuan Province, China, awake mechanically ventilated adults with a Richmond Agitation-Sedation Scale (RASS) score of 0 to +1 requiring closed-system suctioning were enrolled. Dyspnea intensity was assessed using the Dyspnea Visual Analog Scale (D-VAS, 0–10) before suctioning (T0), immediately after suctioning (T1), and 5 min post-suctioning (T2). Peripheral oxygen saturation (SpO 2 ) and heart rate (HR) were recorded simultaneously.
Results
Fifty-three suctioning procedures from 42 patients were included. D-VAS scores increased significantly from 2.8 ± 1.9 at T0 to 6.4 ± 2.1 at T1 (mean increase 3.6, 95% CI: 3.1–4.1, P < 0.001), then decreased to 3.2 ± 1.7 at T2 ( P < 0.001 vs. T1). Dyspnea worsened in 92.5% of procedures at T1, and 15.1% had not returned to baseline at T2. Despite SpO 2 increasing from 97.2 ± 2.1% to 99.1 ± 1.3% at T1, dyspnea worsened substantially, suggesting a potential dissociation between oxygenation status and subjective respiratory distress. These findings should be interpreted within the context of a single-center convenience sample without prospective sample size calculation and the use of a unidimensional dyspnea instrument.
Conclusion
These findings suggest that closed-system suctioning may induce clinically significant but transient worsening of dyspnea that appears independent of oxygenation status. Individual dyspnea assessment during routine suctioning care warrants attention, and confirmatory multicenter studies with prospective power calculations are needed.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Intensive Care Unit, Mianyang Central Hospital, School of Medicine, University of Electronic Science and Technology of China, Mianyang, Sichuan, China.
Zitieren
APA
Liang, L., Wang, S., Liang, Z., Qiu, X., Xie, S., & Xu, J. (2026). Impact of closed-system suctioning on self-reported dyspnea in mechanically ventilated patients: a prospective observational study. Frontiers in Medicine, 13. https://doi.org/10.3389/fmed.2026.1834389
Vancouver
Liang L, Wang S, Liang Z, Qiu X, Xie S, Xu J. Impact of closed-system suctioning on self-reported dyspnea in mechanically ventilated patients: a prospective observational study. Frontiers in Medicine. 2026;13. doi:10.3389/fmed.2026.1834389
BibTeX
@article{Liang2026,
author = {Liang, Lijun and Wang, Simei and Liang, Zhenghua and Qiu, Xiaoli and Xie, Sha and Xu, Jinlong},
title = {Impact of closed-system suctioning on self-reported dyspnea in mechanically ventilated patients: a prospective observational study},
journal = {Frontiers in Medicine},
year = {2026},
volume = {13},
doi = {10.3389/fmed.2026.1834389}
}
EUVIMED